background image

 

User instructions 

 

 

 

ENGLISH

 

User Manual  

SOLENNE SERIES 

Wall mounted  

premix condensing boiler 

 

 

 

 

 

 

 

 
 
 

 

If you smell gas … 

Î

 

DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY 
GENERATE ELECTRICAL DISCHARGES OR SPARKS. 

Î

 

OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY 
CLEAR THE ROOM. 

Î

 

CLOSE ALL GAS TAPS AND VALVES. 

Î

 

CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL FROM A NEAR BY TELEPHONE. 

 
 

Содержание SOLENNE SERIES

Страница 1: ...NOT ACTIVATE ANY ELECTRIC SWITCHES TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS Î OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM Î CLOSE ALL GAS TAPS AND VALVES Î CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL FROM A NEAR BY TELEPHONE ...

Страница 2: ......

Страница 3: ...doubt as to whether the appliance has been tested by an authorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL registered in accordance with current legislation  Make sure that the requirements relating to the air intake and ventilation of the room in which the boiler is to be installed have been com...

Страница 4: ...FESSIONALLY QUALIFIED PERSONNEL FROM A NEAR BY TELEPHONE Boiler controls Control panel LEGEND 1 ON OFF SWITCH 2 HEATING TEMPERATURE CONTROL KNOB 3 D H W TEMPERATURE CONTROL KNOB 4 D H W TEMPERATURE DISPLAY BUTTON KEEP PRESSED FOR 5 SECONDS TO DISPLAY OUTSIDE TEMPERATURE ONLY WITH OPTIONAL OUTDOOR SENSOR 5 SERVICE BUTTON 6 SUMMER WINTER OR SUMMER WINTER MODE SELECTION BUTTON 7 TERMINAL BOARD FOR EX...

Страница 5: ... 6 see fig 1 The boiler will only work for the central heating system The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel The automatic ignition system will light the burner every time there is a demand for room heating In this case the symbol on the control panel will flash SUMMER WINTER mode To switch boiler operation to SUMMER WINTER mode press...

Страница 6: ...hat the boiler may generate on the display 8 see Control panel together with the relative indications and the operations that the user can carry out to reset the boiler If the problem re occurs after the following actions have been taken call for service _E01_ Ionisation block Code E01 lit continuously on the display Check that the gas valve on the boiler and gas meter are open and that there is g...

Страница 7: ...he display Call for Service _E35_ Flame Detection Malfunction Code E35 lit continuously on the display Call for Service _E42_ Fan Speed P C B malfunction Code E42 lit continuously on the display Call for Service NOTE If the boiler is to be left unused for a long period of time the user must do one of the following Make the boiler safe by disconnecting all the power supplies electricity and gas and...

Страница 8: ...PNA Inc 34 Coffin Ave Brewer ME 04412 P 207 942 3636 F 207 942 3737 www pensotti pna com ...

Отзывы: