22
R.A
R.A
R.A
R.A
R.A.I
.I
.I
.I
.I.:
.:
.:
.:
.: pr
pr
pr
pr
prog
og
og
og
ogrrrrra
a
a
a
ammab
mmab
mmab
mmab
mmable par
le par
le par
le par
le para
a
a
a
ameters
meters
meters
meters
meters
N°
DESCRIPTION PARAMETERS
UNIT OF
MIN
MAX
DEFAULT
PARAMETERS
PAR.
MEASURE
(setted in factory)
(setted by techn. assist. centre)
1
GAS TYPE
1 Methane
1-2
2 LPG
3 Methane France
3
INSULATION LEVEL OF BUILDING (+) (*)
min
5
20
5
10
DHW MODE
0 (OFF)
3
1 (Instantaneous)
2 (Mini-tank)
3 (Ext. water-tank with thermostat - A & B cases)
4 (Ext. water-tank with sensor - C case)
11
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
60
12
WATER TANK MAXIMUM SET-POINT
°C
40
80
60
13
DELIVERY TERMPERATURE EXT. WATER TANK
°C
50
80
80
14
DELTA EXTERNAL WATER TANK (ON)
°C
0
10
5
20
CH MODE
0 (OFF)
1
1 (ON)
2 (zone remote control panel)
21
HEATING CIRCUIT MAXIMUM SET-POINT
° C
45
80
80
22
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
40
28
MAX HEATING POWER REDUCTION TIMER
min
0
20
15
29
FORCED HEATING SHUT DOWN TIMER
min
0
20
3
30
HEATING TIMER RESET FUNCTION
-
0
1
0
40
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
41
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
42
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
43
S.A.R.A. BOOSTER FUNCTION
0 (OFF)
1
1 (AUTO)
44
THERMOREGULATION FUNCTION
0 (OFF)
1
1 (AUTO)
45
INCLINATION THERMOREGULATION CURVE (OTC) (*)
-
2,5
40
20
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
0
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
61
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
°C
0
10
4
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
°C
0
10
6
85
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
86
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
0.6
MIX R.S
MIX R.S
MIX R.S
MIX R.S
MIX R.S.I
.I
.I
.I
.I.:
.:
.:
.:
.: pr
pr
pr
pr
prog
og
og
og
ogrrrrra
a
a
a
ammab
mmab
mmab
mmab
mmable par
le par
le par
le par
le para
a
a
a
ameters
meters
meters
meters
meters
N°
DESCRIPTION PARAMETERS
UNIT OF
MIN
MAX
DEFAULT
PARAMETERS
PAR.
MEASURE
(setted in factory)
(setted by techn. assist. centre)
1
GAS TYPE
1 Methane
1-2
2 LPG
3 Methane France
2
BOILER POWER
26 (26kW)
30
30 (30kW)
34 (35kW)
3
INSULATION LEVEL OF BUILDING (+) (*)
min
5
20
5
10
DHW MODE
0 (OFF)
3
1 (Instantaneous)
2 (Mini-tank)
3 (Ext. water-tank with thermostat - A & B cases)
4 (Ext. water-tank with sensor - C case)
11
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
60
12
WATER TANK MAXIMUM SET-POINT
°C
40
80
60
13
DELIVERY TERMPERATURE EXT. WATER TANK
°C
50
80
80
14
DELTA EXTERNAL WATER TANK (ON)
°C
0
10
5
20
CH MODE
0 (OFF)
1
1 (ON)
2 (zone remote control panel)
21
HEATING CIRCUIT MAXIMUM SET-POINT
° C
45
80
80
22
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
40
28
MAX HEATING POWER REDUCTION TIMER
min
0
20
15
29
FORCED HEATING SHUT DOWN TIMER
min
0
20
3
30
HEATING TIMER RESET FUNCTION
-
0
1
0
40
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
41
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
42
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
43
S.A.R.A. BOOSTER FUNCTION
0 (OFF)
1
1 (AUTO)
44
THERMOREGULATION FUNCTION
0 (OFF)
1
1 (AUTO)
45
INCLINATION THERMOREGULATION CURVE (OTC) (*)
-
2,5
40
20
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
0
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
61
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
°C
0
10
4
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
°C
0
10
6
85
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
86
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
0.6
(*) parameters shown only with external sensor connected and parameter 44 in 1 (AUTO).
(+) for well-insulated buildings select values close to 20, for badly insulated buildings choose values close to 5.
T m. =
maximum rated temperature of heating water
T e. =
minimum rated external temperature
OTC =
10 x
Tm. - 20
20 - Te.
Parameter 45 “Inclination of thermoregulation curve (OTC)”
The curve must be chosen according to the geographical area and the type
of installation.
Содержание b11bs
Страница 95: ...95 EXCLUSIVE C A I 86 JP1 AB0X...
Страница 96: ...96 EXCLUSIVE MIX C S I 87 EXCLUSIVE 35 MIX C S I JP1 AB0X...
Страница 97: ...97 EXCLUSIVE R A I 88 JP1 AB0X...
Страница 98: ...98 EXCLUSIVE MIX R S I 89 JP1 AB0X...
Страница 103: ......
Страница 104: ...104 Cod 20029183 09 10 Ed 0 Via Risorgimento 13 23900 Lecco LC ITALY...