1 5  Identification

The products are identified by:

RES
ET

On

Erro

r

RES
ET

On

Erro

r

5.5

bar

Caldaia regolata per:

G20         20 mbar

Paese di destinazione:

ITALIA

Paese di destinazione:

Tipo di apparecchio

Caldaia categoria

:

:

B23

II

2H3+

Pressioni di alimentazione gas:

Regolazione effettuata dal costruttore:

G20 - 20 mbar - 2H METANO

ATTENZIONE

Leggere attentamente il libretto istruzioni

prima  di  installare  e  mettere  in  servizio

l'apparecchio.

(Laterale DX)

Temperatura ambiente:

min. -10°C max. 50°C

Questo apparecchio puó essere installato e

funzionare  all'aperto  o  solo  in  locali

permanentemente ventilati secondo norma

UNI7129.

068411_E0

G20 20 mbar

G30 28-30 mbar

G31 37 mbar

1

1

2

3

1

 

Gas label

.

 

It is applied on the front part of the device and indicates the type of gas used by the modular system and the coun-

try of destination.

2

 

Technical data plate

 

It indicates the technical and performance data.

3

 

Serial number plate

 

This is located on the boiler body and specifies the serial number, model, and furnace power.

Spare parts and/or technical operation require the exact identification of the corresponding model. The absence of, 
tampering with or removing the identification plates or other does not make it possible to reliably identify the product, 
makes any installation and maintenance operation difficult and invalidates the warranty.

1 6  System layout

Control panel

Single heating element

Instrument panel

Pressure gauge

Fuel shut-off cock

Automatic vent valve

Flue Manifold

Venturi tubes

Fan

10 

Air inlet pipe

11 

Ignition detection electrode

12 

Flame inspection window

13 

Burner

14 

Exchanger

15 

Gas inlet

16 

Flow high temperature connection

17 

Flow low temperature connection

18 

Delivery probe pit

19 

Return low temperature connection

20 

Non-return valve

21 

3-way cock (manual)

22 

Return high temperature connection

23 

Water return manifold

24 

Condensate drain manifold

25 

Water flow manifold

26 

Gas manifold

27 

Hose (flue gas exhaust)

28 

Reduction 80/50 (flue gas exhaust)

29 

Check valve (flue gas exhaust)

30 

Shut-off cock

31 

Thermometer pit

32 

Damper device for gauge

33 

Gauge fitting with cock

34 

Temperature gauge

35 

Maximum pressure switch

36 

System filling unit or expansion tank fitting

37 

Hydraulic separator

38 

Drain cock

39 

Condensate drainpipe

40 

Safety cock (5.4 bar)

41 

Single heating element flue gas analysis outlet

42 

Flow probe

43 

Single heating element automatic bleed cock

44 

Safety thermostat

45 

Heating element delivery pipe

46 

Differential water and minimum pressure switch

47 

Pump

48 

Water return cock

49 

Water return union

50 

Return probe

51 

Exhaust flue probe

52 

Hose coupling union (flue gas exhaust)

53 

Gas supply pipe

54 

Gas cock

55 

Gas valve

Содержание 20072002

Страница 1: ...Installation Manual CONDENSING THERMAL MODULES Power Plus Box Installation Manual EN...

Страница 2: ...ta CONFORMITY The Power Plus Box SE modular condensing systems com ply with Directive 2009 142 EC Gas Appliances Directive 92 42 EEC on efficiency requirements and Annex E and Pres Republic Decree n 4...

Страница 3: ...FORMATION 4 1 1 General Safety Information 4 1 2 Precautions 4 1 3 Description of the appliance 5 1 4 Safety devices 5 1 5 Identification 6 1 6 System layout 6 1 7 Coupling configuration 8 1 8 Technic...

Страница 4: ...n densing system at least once a year b This manual is an integral part of the equipment and therefore must be stored carefully and must ALWAYS accompany the modular condensing system even if it is so...

Страница 5: ...er pressure switch and an electronic safety system that controls a delivery sensor and a return sensor The equipment is protected if there is no water or in the case of insufficient circulation Safety...

Страница 6: ...akes any installation and maintenance operation difficult and invalidates the warranty 1 6 System layout 1 Control panel 2 Single heating element 3 Instrument panel 4 Pressure gauge 5 Fuel shut off co...

Страница 7: ...SET On Error RESET On Error 5 5 bar 1 3 2 4 5 6 7 30 8 9 10 31 11 14 15 16 17 19 20 21 10 13 22 43 45 41 46 10 13 47 48 23 24 25 26 27 28 29 18 13 12 32 33 36 37 38 34 35 39 40 42 44 50 51 52 53 54 55...

Страница 8: ...PLUS BOX SE SZ2 VM SB PZ1 PB SE PZ2 SZ1 SZ1 Delivery manifold sensor SZ2 Low system temperature sensor SB Boiler sensor SE Outdoor sensor PZ1 Zone 1 circulator high temperature PZ2 Zone 2 circulator l...

Страница 9: ...loss Tm 70 C 0 5 Flue gas temperature Return temperature 2 5 C max 80 C C CO2 at minimum 9 0 G20 10 4 G30 31 CO2 at maximum 9 0 G20 10 4 G30 31 CO S A at minimum maximum less than 11 91 mg kWh Weight...

Страница 10: ...is outlet 12 Gas valve 13 Gas cock 14 Safety cock 5 4 bar 15 Water flow manifold 16 Water return manifold 17 Hydraulic separator 18 Drain cock 19 Shut off cock 20 High temperature flow fitting 21 Low...

Страница 11: ...70 95 1108 18 61568 1 26135 20 12090 39 6033 58 3216 77 1817 96 1079 17 58719 2 25044 21 11634 40 5828 59 3116 78 1766 97 1051 16 56016 3 24004 22 11199 41 5630 60 3021 79 1717 98 1024 15 53452 4 2301...

Страница 12: ...tr remoto 24V contr remoto Comune Analogic Input Comune T A circ 1 Comune T A circ 2 2 Comune 4 J1 PC BARCODE NTC climatica J11 11 Comune NTC mand circ 2 NTC mand circ 1 Comune Comune NTC bollitore Co...

Страница 13: ...ne Sens Hall Termostato limite Valvola gas 2 1 3 a 9 m J16 NTC fumi J9 J4 a 10 WD J5 T3 PC Main IG SLAVE 2 3 C TS VG SR SF EA ER J10 J17 a m 13 Pressostato Diff PD Circolatore C Circolatore Bus line w...

Страница 14: ...ranty certificate Barcode labels 6 Accessory envelope containing Natural gas to LPG transformation kit valid for Eu rope Door key The following is also supplied positioned on the base inside the modul...

Страница 15: ...N Power Plus Box 100 SE System side connections MI1 High temperature flow manifold 3 MI2 Low temperature flow manifold 3 RI1 High temperature return manifold 3 RI2 Low temperature return manifold 3 IG...

Страница 16: ...ries installation of the modules keeping the following in mind the hydraulic and gas connections must be made on the right side of the control unit when standing in front of the two systems prepare th...

Страница 17: ...16 17 16 POWER PLUS BOX POWER PLUS BOX SE 1 Flue gas exhaust manifold connection 2 Drain 3 Power Plus Box modular system 4 Power Plus Box SE modular system 5 Manifold delivery sensor trap 6 Gas shut o...

Страница 18: ...to add water to central heating systems Use a manual device in stead and record top ups in the system service book b If there are more than one boiler they must all be put into service either contemp...

Страница 19: ...is therefore important to avoid two factors possibly leading to the above mentioned pro cesses i e contact between air and water in the installation and regular topping up with fresh water To elimina...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...oilers com Beretta reserves the right to modify the characteristics and specifications given in this publication at any time and without prior notice as part of its policy of continuous product improv...

Отзывы: