Beretta 20072002 Скачать руководство пользователя страница 14

 

14

2  INSTALLATION

2 1  Unpacking the product

The 

Power Plus Box SE

 condensing system is supplied on 

a pallet, strapped and protected by cardboard packaging. 

Its condition and compliance with what was ordered must 

be checked immediately. The specific characteristics of 

the product are indicated on the outside: model, power, 

product code and serial number. If there is a discrepancy 

between what was ordered and what was received, imme-

diately contact the local agent, warehouse or sales service.

2 2  Opening

Remove the straps (1) and the cardboard packaging (2).

1  Strap

2  Cardboard packaging

3  Pallet

4  Modular condensing system

5  Document envelope containing:

-  Instruction manual

-  Hydraulic test and warranty certificate

-  Barcode labels

6  Accessory envelope containing:

-  Natural gas to LPG transformation kit (valid for Eu-

rope)

-  Door key

The following is also supplied:

positioned on the base inside the modular system:

-  2 - 5” DN 125 - PN 6 flanges complete with gaskets

-  1 - 3” DN 80 - PN 6 flange complete with gaskets

-  polypropylene coupling pipes for the flue gas mani-

fold and condensate outlet

positioned inside the control panel:

-  low temperature boiler/delivery sensor

-  outdoor sensor.

The document envelope (5) must be kept in a safe 

place. Any copies must be requested from 

B

who will send the new documentation within 45 days 

and who reserves the right to charge for the copies.

Do not dispose of packaging material into the envi-

ronment, or leave it within the reach of children, since 

it can become a potential hazard. Dispose of packag-

ing material in compliance with applicable legislation.

4

6

3

5

2

1

Содержание 20072002

Страница 1: ...Installation Manual CONDENSING THERMAL MODULES Power Plus Box Installation Manual EN...

Страница 2: ...ta CONFORMITY The Power Plus Box SE modular condensing systems com ply with Directive 2009 142 EC Gas Appliances Directive 92 42 EEC on efficiency requirements and Annex E and Pres Republic Decree n 4...

Страница 3: ...FORMATION 4 1 1 General Safety Information 4 1 2 Precautions 4 1 3 Description of the appliance 5 1 4 Safety devices 5 1 5 Identification 6 1 6 System layout 6 1 7 Coupling configuration 8 1 8 Technic...

Страница 4: ...n densing system at least once a year b This manual is an integral part of the equipment and therefore must be stored carefully and must ALWAYS accompany the modular condensing system even if it is so...

Страница 5: ...er pressure switch and an electronic safety system that controls a delivery sensor and a return sensor The equipment is protected if there is no water or in the case of insufficient circulation Safety...

Страница 6: ...akes any installation and maintenance operation difficult and invalidates the warranty 1 6 System layout 1 Control panel 2 Single heating element 3 Instrument panel 4 Pressure gauge 5 Fuel shut off co...

Страница 7: ...SET On Error RESET On Error 5 5 bar 1 3 2 4 5 6 7 30 8 9 10 31 11 14 15 16 17 19 20 21 10 13 22 43 45 41 46 10 13 47 48 23 24 25 26 27 28 29 18 13 12 32 33 36 37 38 34 35 39 40 42 44 50 51 52 53 54 55...

Страница 8: ...PLUS BOX SE SZ2 VM SB PZ1 PB SE PZ2 SZ1 SZ1 Delivery manifold sensor SZ2 Low system temperature sensor SB Boiler sensor SE Outdoor sensor PZ1 Zone 1 circulator high temperature PZ2 Zone 2 circulator l...

Страница 9: ...loss Tm 70 C 0 5 Flue gas temperature Return temperature 2 5 C max 80 C C CO2 at minimum 9 0 G20 10 4 G30 31 CO2 at maximum 9 0 G20 10 4 G30 31 CO S A at minimum maximum less than 11 91 mg kWh Weight...

Страница 10: ...is outlet 12 Gas valve 13 Gas cock 14 Safety cock 5 4 bar 15 Water flow manifold 16 Water return manifold 17 Hydraulic separator 18 Drain cock 19 Shut off cock 20 High temperature flow fitting 21 Low...

Страница 11: ...70 95 1108 18 61568 1 26135 20 12090 39 6033 58 3216 77 1817 96 1079 17 58719 2 25044 21 11634 40 5828 59 3116 78 1766 97 1051 16 56016 3 24004 22 11199 41 5630 60 3021 79 1717 98 1024 15 53452 4 2301...

Страница 12: ...tr remoto 24V contr remoto Comune Analogic Input Comune T A circ 1 Comune T A circ 2 2 Comune 4 J1 PC BARCODE NTC climatica J11 11 Comune NTC mand circ 2 NTC mand circ 1 Comune Comune NTC bollitore Co...

Страница 13: ...ne Sens Hall Termostato limite Valvola gas 2 1 3 a 9 m J16 NTC fumi J9 J4 a 10 WD J5 T3 PC Main IG SLAVE 2 3 C TS VG SR SF EA ER J10 J17 a m 13 Pressostato Diff PD Circolatore C Circolatore Bus line w...

Страница 14: ...ranty certificate Barcode labels 6 Accessory envelope containing Natural gas to LPG transformation kit valid for Eu rope Door key The following is also supplied positioned on the base inside the modul...

Страница 15: ...N Power Plus Box 100 SE System side connections MI1 High temperature flow manifold 3 MI2 Low temperature flow manifold 3 RI1 High temperature return manifold 3 RI2 Low temperature return manifold 3 IG...

Страница 16: ...ries installation of the modules keeping the following in mind the hydraulic and gas connections must be made on the right side of the control unit when standing in front of the two systems prepare th...

Страница 17: ...16 17 16 POWER PLUS BOX POWER PLUS BOX SE 1 Flue gas exhaust manifold connection 2 Drain 3 Power Plus Box modular system 4 Power Plus Box SE modular system 5 Manifold delivery sensor trap 6 Gas shut o...

Страница 18: ...to add water to central heating systems Use a manual device in stead and record top ups in the system service book b If there are more than one boiler they must all be put into service either contemp...

Страница 19: ...is therefore important to avoid two factors possibly leading to the above mentioned pro cesses i e contact between air and water in the installation and regular topping up with fresh water To elimina...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...oilers com Beretta reserves the right to modify the characteristics and specifications given in this publication at any time and without prior notice as part of its policy of continuous product improv...

Отзывы: