23
Operation
6005735_0 – 31.03.2021
EN
4.2
Operating the device
The device is controlled via the control panel.
The position of the control panel can be seen by the recess of
the ON/OFF button at any time. The other buttons illuminate
if the device is switched on.
y
Button glows brightly = Function active
y
Button glows dimly = Function not active
Button
Function
ON / OFF, configuration mode access
Recirculated air mode, filter filling control
indicator
Hob lighting
Effect lighting (no function)
Power level 1
Power level 2
Power level 3
Power level POWER
Run-on function
Multifunction button (no function)
After the electrical power is switched on, the device needs
a few seconds to adjust to the surrounding conditions. No
entries are possible during this time. The process is complete
when the buttons illuminate weakly.
4.2.1
Normal operation
D
WARNING!
Fire hazard due to grease residue!
In operation grease residue, which is highly inflammable,
collects in and on the device.
☞
Clean the device properly.
D
To achieve an optimal efficiency in removing cooking fumes:
☞
Turn the device on 1-2 minutes before you start cooking.
This allows the flow of air to build up, and the fumes are
removed at an early stage.
☞
During the cooking process, switch to a power level that
is appropriate for the intensity of the cooking vapours:
y
Power level 1 - lowest fan power
y
Power level 2 - medium fan power
y
Power level 3 - high fan power
☞
If the intensity of the cooking vapours does not subside,
switch to a higher power level.
☞
Switch to the POWER level if frying. After 6 minutes,
the device automatically switches back to power level 3.
To activate the Power level permanently,
the corresponding button must be pushed again.
Then the device doesn’t switch back.
☞
Check the fresh air supply at regular intervals.
☞
Use the device also to reduce other unpleasant smells.
Such as from:
y
Onions and garlic
y
Oven, microwave and steamer
y
Fondue and raclette
☞
Turn on the run-on function when you have finished
cooking.
☞
Turn off the device after use. If the automatic run-on
function is activated, the run-on time (10 minutes) starts
in power level 1.
With use of the BackFlow technology, if a power level is
active then a gentle air flow is routed from the air channel
on the underside of the device to the front air inlet. This air
circulation is necessary. The air channel on the underside of
the device must never be closed off.
After 12 hours without operation, the device (incl. lighting)
automatically switches off.
Содержание BIH 100 GL
Страница 36: ...6005735_0 31 03 2021 ...