This manual contains important instruction for use during installation and 

maintenance of the micro inverter.

To reduce the risk of electrical shock, and to ensure the safe installation and 

operation of the micro inverter, the following safety symbols appear throughout this 

document to indicate dangerous conditions and important safety instruction.

1 Important Safety Information

1.1 Read It First

DANGER

NOTICE indicates a situation that can result in property damage, 

if

 

not

 

avoided

.

Do

 

not

 

use

 

equipment

 

in

 

a

 

manner

 

not

 

specified

 

by

 

the

 

manufacturer

Doing

 

so

 

may

 

cause

 

death

 

or

 

injury

 

to

 

persons

,

 or

 

damage

 

to

 

equipment

.

Be

 

aware

 

that

 

only

 

qualified

 

personnel

 

should

 

install

 

or

 

replace

 

the

 

micro

 

inverters

 

and

 

the

 

cable

 

and

 

accessories

.

Do

 

not

 

attempt

 

to

 

repair

 

the

 

micro

 

inverter

it

 

contains

 

no

 

user

-

serviceable

 

parts

.

 If

 

it

 

fails

contact

 

customer

 

service

 

to

 

start

 

the

 

replacement

 

process

Tampering

 

with

 

or

 

opening

 

the

 

micro

 

inverter

 

will

 

void

 

the

 

warranty

.

If

 

the

 

AC

 

cable

 

on

 

the

 

micro

 

inverter

 

is

 

damaged

 

or

 

broken

do

 

not

 

install

 

the

 

unit

.

Before

 

installing

 

or

 

using

 

the

 

micro

 

inverter

 

read

 

instructions

 

and

 

cautionary

1.2 Safety

 

Instructions

markings in the technical description and on the micro inverter system and the PV 

equipment. 

Connect the micro inverter to the utility grid only after you have completed all 

installation procedures and after receiving prior approval from the electrical utility 

company. 

Be aware that the body of the micro inverter is the heat sink. Under normal operating 

conditions, the temperature is 20°C above ambient, but under extreme conditions the 

micro inverter can reach a temperature of 80°C (176°F). To reduce risk of burns, use 

caution when working with micro inverters. 

Do not disconnect the PV module from the micro inverter without first removing AC 

power. 

Be aware that the micro inverter has field-adjustable voltage and frequency trip 

points that you may need to set, depending upon local requirements. Only an 

authorized installer with the permission and following requirements of the local 

electrical utility should make adjustments.

NOTICE

WARNING

WARNING indicates a hazardous situation which

,

 if not

 

avoided

,

 can result in death or serious injury or moderate

 

injury

.

DANGER indicates a hazardous situation which, if not avoided, 
will result in death or serious injury.

Содержание ECO

Страница 1: ...lation Operation User Operating Manual User Manual V1 1 User Manual V1 1 Address R Actriz Palmira Bastos LT 102 Lisbon Telephone 351 935866092 Email info beonenergy com Skype beonenergy web www beonenergy com ...

Страница 2: ...2 Micro Inverter System 2 1 How It Work 2 2 Optimal Reliability 2 3 Easy of Design 3 Product Information 3 1 Overview 3 2 Major Characteristics 3 3 Datasheet 4 Packing Checklist 4 1 Assembly Parts 4 2 Product Description 5 Planning of Micro Inverter Installation 5 1 Explanations of Symbols on Inverter 5 2 Lightning and Surge Suppression 6 Micro Inverter Mounting and Wiring 7 Commissioning and Oper...

Страница 3: ...nstalling or using the micro inverter read instructions and cautionary 1 2 Safety Instructions markings in the technical description and on the micro inverter system and the PV equipment Connect the micro inverter to the utility grid only after you have completed all installation procedures and after receiving prior approval from the electrical utility company Be aware that the body of the micro i...

Страница 4: ...nd orientation You won t need to install cumbersome traditional inverters Each micro inverter quickly mounts on the PV racking directly beneath each PV module Low voltage DC wires connect from the PV module directly to the co located micro inverter eliminating the risk of personnel exposure to dangerously high DC voltage 05 2 Micro Inverter System The micro inverter system is the worlds most techn...

Страница 5: ...onitoring DC current monitoring Model BeON ECO Input Data DC Max input power 180 300W 50V 24 V Peak power tracking range 24V 50V Operating range Max DC short circuit current 15A Max input current 10A Output Data AC Max output power 250W Nominal output current 1 09A Max output current 1 14A Nominal voltage range 184V 265V Adjustable with Country Deviation Nominal frequency range 46Hz 60 2Hz Adjusta...

Страница 6: ...ith lightning and or surge suppression devices In addition to having some level of surge suppression it is important to have insurance that protects against lightning and electrical surges Symbol Description Dangerous electrical voltage This device is directly connected to public grid thus all work to the inverter shall only be carried out by qualified personnel NOTICE danger This device directly ...

Страница 7: ...o inverter without first removing AC power from the PV system DANGER Installing the micro inverter system involves several key steps Each step listed here is detailed in the following page Step1 Check system configuration Step2 Connect AC power cable and fix T connector Step3 Install inverter Step4 Ground connection Step5 Install the end cap of AC power cable Step6 Connect inverter AC output and a...

Страница 8: ...ralia National Rules NOTICE During installation if the arrays are mono crystalline or polycrystalline solar cells the array should be floating If the arrays are thin film cells the PV negative pole should be grounded NOTICE Strip cable jacket 18mm 25mm Disassemble the Seal Clamp Ring Nut then Insert through the cable Insert each wires into the holes Push he cable to the end Gently try to pull out ...

Страница 9: ...undersides of the micro inverters 1 2 Adhere to all the safety measures described throughout this manual Qualified personnel can use the following troubleshooting steps if the PV system does not operate correctly Do not attempt to repair the micro inverter it contains no user serviceable parts If the micro inverter fails contact customer service to obtain an RMA return merchandise authorization nu...

Страница 10: ...ly check that the AC branch circuit connections cable and AC connections are properly seated Reseat if necessary Check also for damage such as rodent damage Make sure that any upstream AC disconnects as well as the dedicated circuit breakers for each AC branch circuit are functioning properly and are closed 1 2 3 4 5 6 7 8 230 or 240 Volt AC Single Phase 208 Volt AC Three Phase L to N 184 265V AC ...

Отзывы: