The microprocessor controller TC507 allows an exact
and reproduceable control of your kiln. The course of
a firing is shown in a figure which is seperated in up
to 100 segments. One segment always consists of a
ramp (i.e. heat up or cooling) to a certain temperature
followed by a dwell at this temperature. Example:
For each segment the following values have to be
entered:
Temperature increase (or decrease). Can be entered
either in degrees centigrade per hour (e.g. 250°C/h) or
as time (e.g. 2:00 h). For uncontrolled hearing resp.
cooling the value „skip“ is entered.
Final Temperature of the ramp (e.g. 500°C). The ramp
ends at this temperature.
Dwell time at this temperature (e.g. 20 min). The
temperature is held for the time entered.
4
820
Temp
(
°
C)
500
540
0
1
3
2
4
250
°
C/h
350
°
C/h
SKIP
40
°
C/h
0.00h
0:20h
1:00h
0:10h
460
2:00h
Segment
Nr.
0:55h
2:00h
segment operation
0
programme delay for delayed start (not used = 0 min)
1
heating up at 250°C/h to 500°C with 20 min dwell
2
heating up at 350°C/h to 820°C with 10 min dwell
3
cooling at maximum speed (SKIP) to 540°C with 1 hour dwell
4
cooling at 40°C/h to 460°C, no dwell
time
tmp
time
rmp
resp.
dwell
time
rmp
tmp