This fun ction is pro vi ded by the op tio nal
K3-PRT2
Prin ter Inter fa ce.
The Event log ger
The Event log ger is set up as fol lows:
Ø
the Event num ber (
Ev.
) is shown on the left side of
the first line;
Ø
the Event de ta ils (
TYPE
,
IDENT.
,
USER
,
USER ID
,
TIME
) are shown on the se cond line.
Using the Event Log ger:
Ø
Use
A
and
B
to scroll the Events.
Ø
Press
D
to view the Event de ta ils (see abo ve).
Ø
Press
ESC
to step back to the
Event Log ger
menu.
+
The di splay will show the de ta ils of each Event. For exam -
ple, Tam per Events show the TYPE and TIME only.
Zone status
This op tion will al low you to view the sta tus of the zo nes
(Standby, Alarm, Tam
per, Short-cir
cu it or Bypas sed,
and also the Zone vol ta ge le vel). This op tion is im por -
tant du ring in stal la tion and pla ce ment tests.
Do u ble-ba lan ce
zo
nes can si
gnal
Short-cir cu it
,
Standby
,
Alarm
or
Tam per
sta tus.
Ba lan ce zo nes can si gnal
Short-cir cu it
,
Standby
or
Alarm
sta tus.
NC
and
NO
zo nes
can si gnal
Standby
or
Alarm
only. If a zone is abo ut to chan ge sta tus, the di -
splay may show the in ter me dia te sta tus be fo re sho wing
the fi nal sta tus.
+
For exam ple, if a Do u ble Ba lan ce zone is chan ging
from Standby to Tam per, the Zone sta tus op tion
may in di ca te Alarm Sta tus for se ve ral se conds be -
fo re fi nally sho wing Tamper status.
To view the Zone sta tus, work ca re fully thro ugh the fol -
lo wing steps.
From the Instal ler menu:
INSTALLER MENU
Event logger
1.
Using
A
or
B
, se lect the
Zone sta tus
op tion, then
press
ENTER
.
zone n. 001
South entrance
2.
Using
A
or
B
, scroll the zo nes or en ter the zone ID
num ber (three di gits re qui red).
NOTE:
Wrong en tries will be si gnal led by an au di ble er -
ror si gnal.
zone n. 002
Staircase Window
3.
Press
ENTER
to view the sta tus.
Sta
ir
ca
se Win
dow
STBY UNBYPASSED
4.
Press
ENTER
aga in to view the Zone Re si stan ce (in
ohm, see the exam ple be low).
Sta
ir
ca
se Win
dow
4265 ohm
5.
Press
ESC
to go back to the Instal ler menu.
On the con trary, if you press
ENTER
it is pos si ble to
check, one at time, the zone with “Vi bra tion” at tri bu te (if
in pro gram ming fase the same zone has been pro gram -
med with “Vi bra tion” at tri bu te and has been pro gram -
med the sen si ti vity and the pul se num ber):
Zone n. 001
Vi
brat. Test 001
Zone test
This op tion will al low you to test all the par ti tion zo nes
wit ho ut ge ne ra ting alarms. The Test event will be re cor -
ded in the event log ger as: <Alarm - Zone un der test>.
The fol lo wing events may also be re cor ded in the log -
ger: key pad buz zer or ac ti va tion of Out put 1; or key pad
buz zer+ac ti va tion of Out put 1.
From the Instal ler menu:
INSTALLER MENU
Event logger
1.
Using
A
or
B
, se lect the
Zone test
op tion, then press
ENTER
.
Zone test
Logger only
2.
Using
A
or
B
, se lect Test mode, then press
ENTER
.
Partition 001
Test ON
3.
Using
A
or
B
, se lect the Par ti tion the zo nes be long to.
Partition 002
Test ON
4.
Using
ON
or
OFF
re spec ti vely, to ac ti va te/stop the
test for the par ti tion con cer ned. Press
ENTER
to run the
test.
Test running...
NOTE:
The Zone sta tus (Acti va ted or Re sto red)
will be re cor ded in the Event Log ger.
5.
Press
ESC
to go back to the Instal ler menu
8
KYO320