Program Panel
The Con trol pa nel pa ra me ters can be pro gram med via
key pad, re fer to the “PROGRAM PANEL” sec tion for
de ta ils and in struc tions.
Enroll wireless
The
Enrol wi re less
op tion will al low you to en rol wi re -
less de vi ces (de tec tors and keys), and per form the Pla -
ce ment Test.
From the Instal ler menu:
INSTALLER MENU
Even
t logger
1.
Using
A
or
B
, se lect the
Enrol wi re less
op tion:
INSTALLER MENU
Enrol wi
re
less
2.
Press
ENTER
:
ENROLL WIRELESS
Enrol detectors
+
If the Re ce i ver has not been en rol led, the
di splay
will show the fol
lo wing mes
sa ge:
[
WARNING!
____
/
_
No Re ce
i
ver!
_
]
.
3.
Using
A
or
B
, se lect
Enrol de tec tors
,
Enrol WLS
keys
or
WLS Pla ce ment Test
, then press
ENTER
.
From
Enrol sen sors
:
ENROL WIRELESS
Zone 281
4.
Using
A
or
B
, as sign the wi re less de tec tor to a zone,
then press
ENTER
:
Zone 281
Se
rial #:000000
Enter the Elec tro nic Se rial Num ber (ESN) of the wi re -
less de tec tor. The ESN (6 di gits) is prin ted on the back
of each wi
re less de
vi ce. This Con
trol pa
nel ac
cepts
6-di git ESNs only. To cor rect wrong en tries, press e
then en ter the cor rect di git. The ESN may com pri se he -
xa de ci mal di gits (A, B, C, D, E and F: use
A
,
B
,
C
,
D
,
ON
and
OFF
, re spec ti vely). The ESN will al low the Con trol
pa nel to iden tify the wi re less de vi ce.
+
NOTE:
To unen
rol wi
re less de
tec tors, en ter the
ESN 000000 then press
ENTER
to con firm.
5.
Press
ENTER
.
ENROL WIRELESS
Zone 281
6.
Use
A
or
B
to con ti nue en rol ling.
Accep tan ce will be con fir med by the fol lo wing mes sa ge:
ENROL WIRELESS
Enrol ok!
When all the wi re less de tec tors have been en rol led,
press
ESC
to go back to step 3 then, if you want to en rol
wi re less keys, se lect the
Enrol WLS Keys
op tion:
Enrol WLS Keys
ENROL WIRELESS
Enrol WLSKey
4a.
Press
ENTER
.
ENROL WIRELESS
Wireless key 001
5a.
Using
A
or
B
, se lect the wi re less key to be en rol led,
then press
ENTER
.
Wireless key 001
Se
rial #: 000000
Wi re less keys are en rol led in the same way as wi re less
de tec tors. When you have en
rol led all the wi
re less
keys, press
ESC
to go back to step 3 then se lect the
Pla ce ment Test
op tion, in or der to test the tran smis -
sion si gnal bet we en the Re ce i ver and the wi re less de -
tec tors. All pla
ce ments sho
uld be te
sted be
fo re
mo un ting the wi re less de tec tors.
ENROL WIRELESS
Pla
ce
ment test
4b.
Press
ENTER
.
WLSplacementTest
Zone 281
5b.
Using
A
or
B
, se lect the zone of the wi re less de tec -
tor to be te sted, then press
ENTER
.
Wait re
sult...
6b.
Acti va te the wi re less de tec tor (re fer to “Acti va ting
Wi re less De tec tors”), then check the Test re sult on the
di splay.
Wait re
sult..
Good!
If the re sult is
good
, run fur ther tests un til you ob ta in
three con se cu ti ve
good
re sults. Press
ESC
to go back
to step 6b. If the re sult is
bad
, move the De tec tor to anot -
her lo ca tion and re pe at the test. So me ti mes a mat ter of a
few in ches can cor rect a Bad re sult.
If an
Error
is si gnal led, en rol the wi re less de tec tor aga in.
To go back to the Instal ler menu, press
ESC
.
KYO320
KEYPAD OPERATIONS
13