ALL the
AND-Zo nes
de tect vio la tion wit hin the set time.
Press
ENTER
to go back to step 3.
PROGRAMMING
Configuration
Outputs
From the PROGRAMMING menu:
PROGRAMMING
Con
fi
gu
ra
tion
1.
Using
A
or
B
, se lect the
Out puts
op tion.
PROGRAMMING
Outputs
2.
Press
ENTER
.
Output n. 001
Output 001
3.
Using
A
or
B
, se lect the Out put to be pro gram med
4
,
then press.
De
scri
ption
Output 001
4.
Enter the Out put la bel (re fer to “Edi ting a text” un der
“Using the Key pad”), then press
ENTER
.
Output 001
Mo
no
stable
5.
Using
A
or
B
, se lect the Out put
Type
(
Mo no sta ble
or
Bi sta ble
), then press
ENTER
.
Output 001
Su
perv.norm.clo
6.
Using
A
or
B
, se
lect the Out
put
Po la rity
:
Su -
perv.norm.clo
(re fer to “Nor mally clo sed” and “Su per -
vi sed”),
Nor mally open
or
Nor mally clo
sed
, then
press
ENTER
.
+
Only Out puts 1, 2 and 3 of KYO 320
can be pro -
gram med as
Su perv.norm.clo
.
Follow n. ---
None
7.
Enter the ID num ber of the Out put which will be trac -
ked by the Out put con cer ned. Enter all ze ros if the Out -
put is not to track anot her Out put.
The key pad will emit an au di ble er ror si gnal, if you:
Ø
at tempt to pro gram a va lue ot her than “
None
”
for an
Out put which is as so cia ted with an event;
Ø
at tempt to pro gram an Out put which has been pro -
gram med to track anot her Out put;
Ø
at tempt to pro gram the se lec ted Out put.
Press
ENTER
.
Options
Reser
ved -
8.
Using
ON
or
OFF
, ena ble/di sa ble the
Re ser ved
at tri -
bu te (“
û
” me ans ena bled, and “
-
” di sa bled).
+
The
Re ser ved
and
Fol low No.
at tri bu tes ex clu de
each ot her au to ma ti cally. The
Re ser ved
Out puts
can not be as so cia ted with events.
Press
ENTER
:
Ass.timer n. ---
None
9.
Using
A
or
B
, se lect the Ti mer which will con trol the
Out put, then press
ENTER
:
ON
time
Min. 003
10.
Using
A
or
B
, se lect Mi nu tes or Se conds for the
ON
time
, then en ter the ON time for the Out put. Va lid en -
tries: 0.2 to 25.4 se conds in steps of 0.2 or 1 thro ugh
127 mi nu tes in steps of 1 mi nu te.
Press
ENTER
.
Off time
Sec. 006
11.
Enter the amo unt of time that must elap se (af ter
Out put re sto ral) be fo re the Out put can be re ac ti va ted.
The
OFF time
can be set for Mo
no sta ble Out
puts
ONLY. Va lid en tries: 1 thro ugh 255 se conds in steps of
1 se cond.
Press
ENTER
:
Oscil
la
tion
None
12.
Using
A
or
B
, se lect the
Half Cycle
of the oscil la -
tion. The Out put will ac ti va te for the pro gram med time,
re sto re to standby for the same amo unt of time, and
then re ac ti va te.
Va lid en
tries: 200 thro
ugh 1400 msec (mil
li se conds;
1000 msec = 1 se cond) in steps of 200 msec. Press
E
:
KYO320
PROGRAM PANEL
25
4
Outputs relating to M-IN/OUT expanders programmed as Input and Output Expanders are NOT all usable, even
if they are shown on the display. For example, if Output Expander no. 1 is an M-IN/OUT Expander programmed
as an Expander with 4 Zones + 2 Outputs, Outputs 07, 08, 09 and 10 are NOT usable. In general, Outputs
[3+(x*6)], [3+(x*6)], [5+(x*6)] and [6+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Zones + 2
Outputs, and Outputs [5+(x*6)] and [6+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Outputs
+ 2 Zones, where “x” is the address of the Expander, are NOT usable.