![Bentel Security KYO 320 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/bentel-security/kyo-320/kyo-320_installation-manual_2735374026.webp)
Ci
cles
Nu
mber 01
13.
Using
A
or
B
, set the num ber of
Cycles
for the Out -
put con cer ned. The
Cycles
can be set for the Mo no sta -
ble Out
puts only. Va
lid en
tries:
1
thro
ugh
31
or
Ti me less
. Press
ENTER
to go back to step 3.
Partition
From the Pro gram ming menu:
1.
Using
A
or
B
, se lect the
Par ti tions
op tion.
PROGRAMMING
Partition
2.
Press
ENTER
:
Partition n. 001
Partition 001
3.
Press
A
or
B
to se lect the re qui red par ti tion, then
press
ENTER
.
De
scri
ption
Partition 001
4.
Enter the par ti tion la bel (re fer to “Edi ting a text” un der
“Using the Key pad”), then press
ENTER
.
Entry time
mm.ss. 00.30
5.
Enter the time (in mi nu tes and se conds) the system
must wait be fo re ge ne ra ting an
Alarm on zone
event
af ter vio la tion of an
Entry de lay
zone, then press
E
.
Exit time
mm.ss 00.15
6.
Enter the
Exit time
(in mi nu tes and se conds). Vio la -
tion of an Armed
Exit De lay
zone will ge ne ra te the pro -
gram med
Exit time
. If vio la tion ends be fo re the
Exit
time
ex pi res
the zone will not ge ne ra te the
Alarm on
zone
event.
Press
ENTER
to con ti nue.
Last exit time
mm.ss 00.15
7.
Enter the
Last exit
time (in mi nu tes and se conds),
then press
ENTER
. Vio la tion of a
Last exit
zone will
ge ne ra te the
Last exit
time of the par ti tion the zone be -
longs to. This fe a tu re will al low the system to Arm as
soon as the
Last exit time
ex pi res. Va lid en tries for
Entry
,
Exit
and
Last exit
ti mes: 0 mi nu tes 0 se conds
thro ugh 59 mi nu tes 59 se conds.
Auto arm timeout
Min. 010
8.
Enter the time (in steps of 1 mi nu te) of the
Auto-arm
ti me o ut
si gnal.
Va lid en tries: 1 thro ugh 240 mi nu tes.
Press
ENTER
to con ti nue.
Options
Au
toArm del.sigx
9.
Using
A
or
B
, se lect the
Au toArm del. sig.
(re fer to
“Au to arm Si gnal”),
Au to re set
(re fer to “Au to re set on
Arming”),
Di sarm with mem.
(re fer to “Di
sarm with
alarm me mory”) or
Con firm Alarm
(re fer to “Di sarm
with alarm me mory”) then, using
ON
or
OFF
, re spec ti -
vely, ena
ble or di
sa ble the op
tion con
cer ned, then
press
ENTER
.
If you se lect the
Con firm Alarm
op tion, you must en ter
the re spec ti ve
Con firm time
(in steps of 1 minute).
Va lid en tries: 30 to 60 minutes.
Con
firm time
Sec. 0060
Press
ENTER
to con ti nue.
Ne
gli
gen
ce time
None
10.
Enter the
Ne gli gen ce time
(in steps of 1 mi nu te). If
the
Ne gli gen ce time
of a par ti tion ex pi res, the Con trol
pa nel will ge ne ra te the re spec ti ve
Ne gli gen ce
event.
The
Ne gli gen ce time
of a par ti tion will re fresh each
time the par ti tion is Armed.
Va lid en tries: 1 to 60000 mi nu tes, or en ter all ze ros to
set
None
.
Press
ENTER
to con ti nue.
Ext.r.toArmDelay
min. 05
11.
Enter the
Exten ded Re
ady-to-Arm de
lay
, then
press
ENTER
.
Patrol Time
Min. 00010
12.
Enter the re le vant
Pa trol Time
, then press
ENTER
.
Inhi
bitArming---
None
13.
Using
A
or
B
, se lect the Ti mer that will fil ter Arming
com mands, then press
ENTER
:
Inhi
bitDi
sar ---
None
14
.Using
A
or
B
, se lect a Ti mer to fil ter the Di sarm com -
mands, then press
ENTER
.
26
KYO320