LEDs On the Enhanced Keypad

1.3

LEDs on the Enhanced Keypad

The enhanced keypad features three LEDs to provide status information. The
following table describes these three LEDs.

4

1 - INTRODUCTION

Key

Description

The FWD key commands the motor to begin running in the Forward direction.

The STOP key, if enabled by parameter Stop Key (see RSi SX Parameter Configuration
manual), commands the motor to stop using the type of stop configured by parameter Stop
Mode (see RSi SX Parameter Configuration manual) and using the active deceleration ramp.
If a fault occurs, the STOP key resets the fault.

Table 1: Functions of the Keys on the Enhanced Keypad

FWD

LED Name

Duration

Operating Condition

POWER

Continuous

The drive is powered-up.

WARNING

Continuous

Abnormal operation is detected, but the abnormality is
greater than a warning. The drive will halt operation
when a fault is detected.

FAULT

Continuous

Abnormal operation is detected, but the abnormality is
greater than a warning. The drive will halt operation
when a fault is detected.

Table 2: LEDs on the Enhanced Keypad

STOP

Содержание ENHANCED KEYPAD

Страница 1: ...The Leader In Solid Motor Control Technology Publication 890020 05 01 2005 Benshaw Inc All Rights Reserved Enhanced Keypad Manual...

Страница 2: ...and Displays of the Enhanced Keypad 6 2 INSTALLATION 16 2 1 Inspection Upon Receipt 16 2 2 Components of Installation Kit 16 2 3 Instructions for Panel Mounting 17 2 4 Connecting the Keypad to the RS...

Страница 3: ...1 Introduction 1...

Страница 4: ...monitor important parameters Figure 1 shows the enhanced keypad Keys on the Enhanced Keypad 1 2 Keys on the Enhanced Keypad Table 1 on page 3 describes the functions of the keys found on the enhanced...

Страница 5: ...c keypad allows you to set the value of a parameter by keying in the value rather than by scrolling to the desired value The function of this key the up arrow key is dependent on the mode of the keypa...

Страница 6: ...d by parameter Stop Mode see RSi SX Parameter Configuration manual and using the active deceleration ramp If a fault occurs the STOP key resets the fault Table 1 Functions of the Keys on the Enhanced...

Страница 7: ...rious displays The following figures are examples of what is shown in the display window of the Enhanced Keypad during Monitor MON Parameter PAR Operate OPR and Direct Parameter Access DIR modes READY...

Страница 8: ...Operate Mode The fourth line shows status information drive status output frequency and active control source Figure 8 on page 7 shows the fourth line of the display with the various codes that may b...

Страница 9: ...un command present but not reference Drive is accelerating Drive is decelerating Drive running in Forward at speed Drive running in Reverse at speed DC injection braking is active Drive stopped from t...

Страница 10: ...ial link is in partial control reference from serial link Terminal strip if Local Remote switching not enabled Terminal strip speed control with keypad Start Stop 3 Letter Code for Control Path FLTED...

Страница 11: ...r in the group Use the down arrow key to scroll to the desired parameter 5 Press ENT 6 The value of the parameter will now be shown on the second line of the display Note that this value may be an act...

Страница 12: ...Operate Mode press SHIFT OPR F2 or navigate to it via the Menu Display mode The Direct Parameter Access Mode In the Direct Parameter Access Mode you may navigate directly to a parameter by entering th...

Страница 13: ...meter groups To return to the Operate Mode press SHIFT OPR F2 or navigate to it via the Menu Display mode The Menu Display Mode The Menu Display Mode may be thought of as the hub on which all the othe...

Страница 14: ...t must first be stored in the RSi SX via parameter AFN 90 Param STO RCL The customer set of parameters may then be uploaded to the EKP for transport to another SX drive To upload the parameter set per...

Страница 15: ...e MCP code revision of the source drive for example MCP3 90 and The application number being transferred for example b01V124 During the download operation the display will indicate EKP DRV Once the do...

Страница 16: ...Notes 14 1 INTRODUCTION...

Страница 17: ...2 Installation 15...

Страница 18: ...hipping agent should be notified Components Of Installation Kit 2 2 Components of Installation Kit After checking that the correct keypad arrived in good condition verify that all components for insta...

Страница 19: ...aded inserts on the reverse side of the enhanced keypad and tighten finger tight 4 Place the enhanced keypad on the enclosure so that the threaded studs slide through the mounting holes drilled into t...

Страница 20: ...n Enabling Start Stop Reference Control 2 5 Enabling Start Stop Reference Control Enter the direct parameter mode as described on page 10 Select parameter 875 The valid settings are SKP Drive can be m...

Страница 21: ...of Enhanced Keypad Centerline of Enhanced Keypad 5 75 146 mm 3 18 80 8 mm 1 75 44 5 mm 0 218 5 5 mm diameter 0 218 5 5 mm diameter 0 875 22 2 mm diameter Figure 12 Drill Template for Panel Mounting z...

Страница 22: ...Notes 20 2 INSTALLATION...

Страница 23: ...Revision History Revision Date ECO 00 19 11 02 890020 05 00 Initial Release 01 29 03 05 ECO 0982...

Страница 24: ...Delta Two Speed Part Winding and Reversing Starters Custom OEM Controls Sales and Service United States Pittsburgh Pennsylvania Dayton Ohio Syracuse New York Boston Massachusetts Wilmington Delaware...

Отзывы: