30
tsm1
Adjusts the slowdown phase in the opening and closing of the M1 motor.
Value expressed as a percentage on the entire run.
1-99 (20%)
tsm2
Adjusts the slowdown phase in the opening and closing of the M2 motor.
Value expressed as a percentage on the entire run.
1-99 (20%)
pmo1
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the opening phase at normal speed - Motor 1
1-99-(30%)**
pmc1
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the closure phase at normal speed - Motor 1
1-99-(30%)**
pmo2
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the opening phase at normal speed - Motor 2
1-99-(30%)**
pmc2
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the closure phase at normal speed - Motor 2
1-99-(30%)**
pso1
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the opening phase at slowdown speed - Motor 1
1-99-(30%)**
psc1
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the closure phase at slowdown speed - Motor 1
1-99-(30%)**
pso2
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the opening phase at slowdown speed - Motor 2
1-99-(30%)**
psc2
Adjusts the intervention threshold of the anti-crushing device* (amperometric sensor)
during the closure phase at slowdown speed - Motor 2
1-99-(30%)**
tls
SERL (Service light) enabling time outputs AUX1/AUX2.
On each manoeuvre, the contact closes for the time set.
See connection screen Figure 16/17
1-240-(60s)
t2ch
Enabling time of outputs AUX1/AUX2 when set as second radio channel.
0: Bistable output, the status of the output switches on each command received.
1-250: switching time in seconds
0-250-(1s)
tloc
Electric lock enabling time.
Value expressed in 1/10s (0=0s - 50=5s)
0-50
(10=1s)
vloc
Electric lock power supply voltage.
0: 12V - 1:24V
0-1-(0)
sasc
Sets a short inversion once the closure limit switch point has been reached.
It may be useful to facilitate the manual release of the gate.
Value expressed in 1/10 (0=0s - 40=4s)
0-40 (10)
saso
Sets a short inversion once the opening limit switch point has been reached.
It may be useful to facilitate the manual release of the gate.
Value expressed in 1/10 (0=0s - 40=4s)
0-40 (5)
seav
Adjusts the intervention threshold of the anti-crushing device (encoder) during the
phase at normal speed.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
0-99-(1%)
sear
Adjusts the intervention threshold of the anti-crushing device (encoder) during the
slowdown phase*.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
0-99-(1%)
aux1
Configures the AUX1 output operating mode.
0: SCA output (default)
1: radio 2ch output
2: courtesy light output (based on the time set by TLS parameter). See Fig.16
3: zone light output (always on with motor in motion and during TCA count). See
Fig.16.
4: Photo-test Used to power the transmitters of the photocells in TEST mode.
5: Flashing output, copies the behaviour of the BLINK output
6: Alarm output. If the photocells remain engaged for over double the TCA set time,
the contact closes.
ATTENTION!! The 24Vdc LED lamps, due to inrush current, cannot be directly connected
to the AUX outputs, use a decoupling relay.
0-6 (0)
aux2
Configures the AUX2 output operating mode.
0: SCA output (default)
1: radio 2ch output
2: courtesy light output (based on the time set by TLS parameter). See Fig.17
3: zone light output (always on with motor in motion and during TCA count). See
Fig.17.
4: Photo-test Used to power the transmitters of the photocells in TEST mode.
5: Flashing output, copies the behaviour of the BLINK output
6: Alarm output. If the photocells remain engaged for over double the TCA set time,
the contact closes.
ATTENTION!! The 24Vdc LED lamps, due to inrush current, cannot be directly connected
to the AUX outputs, use a decoupling relay.
0-6 (1)