29
123919 Rev C 5-17-18
EndFlo
60
Figure 10.1
COdE
10
How to Set the End Flow Rate
Menu Code 10
This mode changes the flow rate at which the dispenser will determine that the vehicle tank is full. The
dispenser will continue the fill as long as the measured flow rate remains above this set-point.
It also
sets the maximum flow rate allowed before displaying a High Flow Error (error 21).
How to Program the Dispenser for Operation
To select a slow flow amount in gallons or liters, follow
this procedure:
1. After the Manager’s Mode has been accessed, press
the number 1 and 0, then the
MODE
button on the
keypad.
If the dispenser has not been programmed since it
came from the factory, the number 60 appears in the
main display. This is the default setting. The price
display shows the dispenser is in Menu Code 10 (see
Figure 10.1).
2. To change the setting, use the 0 through 9 buttons on
the keypad to enter a new time (seconds). The
software allows a maximum value of 99.
3. Once the
ENTER
button has been pressed then the
Hi Flow speed is displayed (see figure 10.2).
4. To change the setting, use the 0 through 9 buttons on
the keypad to enter the new flow rate. The Default
setting is 60 GPM. The range is 0 to 60 GPM.
NOTE: If an error is made, press the correct number.
The new number replaces the error.
5. When the correct setting appears in the mass display,
press the
ENTER
button to save the selection.
6. Press the
CANCEL
button to exit this menu code.
Hi Flo
60
Figure 10.2
COdE
10