background image

  

123919 Rev C 5-17-18 

 

 

 

Bennett Natural Gas Series 

Natural Gas Series Remote Dispensers

 

 
 

Operator’s Manual 

Only Trained Personnel May Work on This Equipment 

 

 
READ THIS MANUAL 

This manual has important information for safe installation and 
operation of this equipment.  Read and understand this manual 
before applying power.  Keep this manual and tell all service 
personnel to read this manual.  Bodily injury, death or damage 
to the equipment could be the result of not completely following 
instructions. 

For new manuals, FAX to: 

BENNETT MARKETING SERVICES 
 (231)799-6202

 

or visit our web page at: 

http://www.bennettpump.com

 

Bennett 1218 E. Pontaluna Road, Spring Lake, MI 49456

 

USA 800-235-7618 ~ Outside USA 231-798-1310  

[email protected] ~ www.bennettpump.com

 

Includes Instructions For: 
Sales Operation 
Reading Totals 
Programming 
Diagnostics 
Maintenance 

Содержание Natural Gas Series

Страница 1: ...Keep this manual and tell all service personnel to read this manual Bodily injury death or damage to the equipment could be the result of not completely following instructions For new manuals FAX to B...

Страница 2: ...e Per Mass Display Options 33 Menu Code 15 Fleet Option 35 Menu Code 18 Money Totals Calculation Method 36 Menu Code 21 Dispenser Communication Type 37 Menu Code 22 Dispenser and PLC Address 38 Menu C...

Страница 3: ...ical parts of the dispenser dry WARNING Training is needed in the installation service or maintenance of this equipment dispenser pump console control box before working on it Maintenance repairs must...

Страница 4: ...connect all power and relieve pressure to this equipment and associated pump during installation service or any maintenance i e changing filters DANGER CNG is flammable NO SMOKING OR OPEN FLAME DANGER...

Страница 5: ...ply of a purge air blower 5 7 High Resolution Color Display with optional Alphanumeric Keypad 1 A self monitoring meter will prevent product flow in the event of a malfunction 2 Diagnostic software sy...

Страница 6: ...ack up systems are provided A 12 volt DC sealed lead acid battery works in conjunction with the Totals Display Recall switch to display the last sale data or pump totals when AC power is interrupted T...

Страница 7: ...Once the totals mode is entered the next totals are displayed tapping the magnet over the mass units print beside the Main Display By successively tapping over the mass units print all totals can be...

Страница 8: ...on the side of the dispenser To operate the dispenser remove the nozzle from the holder There is a flapper that will automatically drop down Once the flapper drops down a switch tells the CPU Board th...

Страница 9: ...rculation process 7 Once the recirculation is complete the dispenser will begin to fill the vehicle s tanks 8 Once the tank is full the dispenser will go into a Paused State 9 If the vehicle has two t...

Страница 10: ...displayed If YES is selected proceed to step two 2 Remove the nozzle from the holder see figure D 2 and attach it to the fill adaptor on the vehicle s tank 3 Select the product select button see figur...

Страница 11: ...ads in whole unit DGE increments see figure D 5 NOTE Because of rounding methods used and the nature of electronic totals versus an analog device such as an electro mechanical totalizer electronic tot...

Страница 12: ...tal money amount for the dispenser is 1 234 567 89 the display appears as in Figure T 1 The price display window reads P 1 1 1 for Product 1 Money Total Menu Code 1 To read the mass totals on the disp...

Страница 13: ...gnetic Reed Switch follow this procedure 1 To enter the totals mode hold the black Access Magnet over the mass units print beside the Main Display see figure T 6 When the first Money totals appear rem...

Страница 14: ...ve been displayed tap the magnet over the mass units print again to view the Menu Code 2 Meter Totals for Product 1 The display appears as in Figure T 7 when the display is in Menu Code 2 By successiv...

Страница 15: ...the 2 button and then the MODE button on the keypad The main display appears similar to Figure T 7 The main display shows the electro mechanical total The total number is carried to three decimal pla...

Страница 16: ...side the Main Display see figure T 10 The last sale in progress is displayed for 30 seconds Record the last sale information 2 To redisplay the last sale information after the timer has turned the dis...

Страница 17: ...anager s keypad is properly connected the dispenser will automatically enter the managers programming mode The dispenser s display will read Enter side 1 5 Press the Enter Button on the Manager s keyp...

Страница 18: ...ion sequence 13 Beeper Tone Program to set beeper tone options 14 Price Display Program to set the way price displays operate 15 Fleet Option Program to set Fleet system interface compatibility 18 Mon...

Страница 19: ...mory for the first time or following a RAM memory clear follow the menu codes in order as they are listed in the Initial Setup sequence below Each Menu Code can be pro grammed individually However in...

Страница 20: ...hen access is gained the dashes disappear and the price display appears as in Figure 3 2 If the dashes do not appear the access code entered did not match the code stored in memory Press the CANCEL bu...

Страница 21: ...OPERATE mode by unplugging the manager s keypad from the dispenser Then re enter the ATTENDANT mode by plugging the keyboard back in 2 Press ENTER for Side 1 3 Press the 3 button and then the MODE bu...

Страница 22: ...d the Main Display zeros and indicates the new digit in the right most digit The Price display continues to flash the old price see figure 4 2 When the correct price appears in Main Display press the...

Страница 23: ...o mechanical totals follow this procedure 1 After the Manager s Mode has been accessed press the 5 button and then the MODE button on the keypad A mass amount appears in the sales mass display New dis...

Страница 24: ...enter each menu To review or speed program the Menu Code settings follow this procedure 1 Press the 6 button and then the MODE button on the keypad The main display shows the configuration of the dis...

Страница 25: ...PSI 2 3 600 PSI 5 The number of Tiers 1 1 Tier 2 2 Tier Methane detectors controlled by dispenser 0 No detectors installed 1 Detector address 2 installed 2 Detector address 3 installed 3 Both detecto...

Страница 26: ...oint enter either 1 or 2 for the number of tiers that will be used When the correct option number appears in the main display press the ENTER button to save the selection and the screen will appear as...

Страница 27: ...r a sample of the decimal display for each selection The price in Selection 0 is in dollars The price in Selection 6 is in cents DECIMAL PLACEMENT SELECTIONS MONEY MASS PPM DISPLAY DISPLAY DISPLAY Mas...

Страница 28: ...es indicate the No Flow Time Out amount is an infinite amount or that Menu Code 9 is disabled With this setting the dispenser s valves will remain on indefinitely after the pump handle lever is put in...

Страница 29: ...been programmed since it came from the factory the number 60 appears in the main display This is the default setting The price display shows the dispenser is in Menu Code 10 see Figure 10 1 2 To chang...

Страница 30: ...d press the number 1 and 1 then the MODE button on the keypad The price display shows the dispenser is in Menu Code 11 If the dispenser has not been programmed since it came from the factory the numbe...

Страница 31: ...er 1 and 2 then the MODE button on the keypad The price display shows the dispenser is in Menu Code 12 see figure 12 1 If the dispenser has not been programmed since it came from the factory the numbe...

Страница 32: ...options in Menu Code 13 follow this procedure 1 After the Manager s Mode has been accessed press the number 1 and 3 then the MODE button on the keypad The price display shows the dispenser is in Menu...

Страница 33: ...to the top display and cash price to the bottom display 1 The POS sends the credit price to the bottom display and cash to the top display requiring FLIP to be turned on The Digit Option is used to p...

Страница 34: ...setting for the Flash option Press ENTER to see the Dash option See Figure 14 2 This is the default setting for the Dash option Press ENTER to see the FLIP option See Figure 14 3 This is the default s...

Страница 35: ...lt To select a different option in Menu Code 15 follow this procedure 1 After the Manager s Mode has been accessed press the number 1 and 5 then the MODE button on the keypad The price display shows t...

Страница 36: ...f calculation default 1 No rounding Cross multiplication method of calculation Mass x PPM To select a different option in Menu Code 18 follow this procedure 1 After the Manager s Mode has been accesse...

Страница 37: ...he MODE button on the keypad The price display shows the dispenser is in Menu Code 21 If the dispenser has not been programmed since it came from the factory the default setting is 0 for Current Loop...

Страница 38: ...tton on the keypad The PPM display shows the dispenser in Menu Code 22 If the dispenser has not been programmed since it came from the factory the number 0 appears in the main display This is the defa...

Страница 39: ...shows the total money amount For example If the total money amount for the dispenser is 7 890 123 45 the display appears as in figure 26 1 The price display window reads P 1 1 d for Product 1 Money T...

Страница 40: ...ess the button Remember only the number of products selected in Menu Code 7 will be displayed see figure 26 5 CAUTION THE FOLLOWING PROCEDURE ZEROS ALL THE SHIFT MONEY MASS AND COUNTER TOTALS IN THIS...

Страница 41: ...he number 2 and 7 then the MODE button on the keypad The first display shows the current electronic cali bration correction constant of the configured me ter See Figure 27 1 Use the up arrow button or...

Страница 42: ...be lost in the hose An Ad value of 1 000 will result in the dispenser sub tracting the first 1 000 units of mass from the sale for each recirculation fill cycle D1 D2 C1 C2 dT Fd FCF FT F0 are calibr...

Страница 43: ...an error is made press the correct number The new number will replace the error 3 When the Correct option number appears in the main display press the ENTER button to save the selection 4 Press the CA...

Страница 44: ...ass of Product 1 The bottom left price display shows that it is displaying side 1 See figure 29 1 2 To change the mass press the numeric keys on the Manager s Keypad until the desired number appears o...

Страница 45: ...Pressure Bank Default To program the bank follow this procedure 1 After the Manager s Mode has been accessed press the number 3 and 5 then the MODE button on the keypad see figure 35 1 If the dispens...

Страница 46: ...display will say COLd StArt for approximately 45 seconds see figure 49 2 3 After 45 seconds the display will act like the manager s keypad was plugged in for the first time see figure 49 3 The passwo...

Страница 47: ...is the default set ting 2 To disable the instruction prompt press the 0 button on the keypad NOTE If an error is made press the correct number The new number replaces the error 3 When the correct opti...

Страница 48: ...alve limit switches There are two options for this code 0 Disable Valve Limit Switches Default 1 Enable Valve Limit Switches 1 After the manager s mode has been accessed press the numbers 6 and 2 then...

Страница 49: ...ispenser to be low priority typically a dispenser used to fill large tanks When a dispenser is programmed as a low priority the fill process is temporarily paused when a customer has started a standar...

Страница 50: ...ser is in Menu Code 68 See figure 68 1 2 The dispenser defaults to 1 reporting temperatures in units Celsius regardless of what is displayed on the face of the dispenser To report temperature in the s...

Страница 51: ...he high bank valve 8 Activates all valves on side two 9 Activates all fill valves and access valves CNG 1 Sided 2 Hoses Only Limit Switch statuses If present will appear as follows C Closed O Open Bla...

Страница 52: ...00 F To set the temperatures in mode 85 follow this procedure 1 After the Manager s Mode has been accessed press the number 8 and 5 then the MODE button on the keypad see figure 85 1 2 To program the...

Страница 53: ...tested again To set the set points in mode 85 follow this procedure Continued from Page 50 7 Now the Automatic Vent Down limit is displayed see figure 85 4 8 The vent close pressure may be set from 0...

Страница 54: ...8 1 2 The default value for this is 120 This means that it will reset after 120 seconds of no communication Set this from 5 seconds to 200 seconds 3 Press the numeric keys to enter the desired time fo...

Страница 55: ...try where the dispenser is located Use the numeric keypad to select an option 1 GGE Gasoline Gallon Equivalent 2 GLE Gasoline Liter Equivalent 3 DGE Diesel Gallon Equivalent 4 DLE Diesel Liter Equival...

Страница 56: ...Counter 0 2 Software Release Number 6 3 Cold Start Counter 0 3 Software I D Number CKsum 6 4 Reserved 1 Display Segment Test 6 5 Reserved 2 Fault History 6 6 Reserved 3 CPU Test Error 99 6 7 Reserved...

Страница 57: ...hows the dispenser is in Diagnostics Level 0 2 The current level of software installed in the dispenser is displayed which will change from version to version Press ENTER to move to the next level of...

Страница 58: ...nts will be displayed See figure D 5b Press the CANCEL button to exit this code Press the CANCEL button twice to exit Diagnostics Diagnostic Code 2 Error History The error log file provides 40 entries...

Страница 59: ...utton to exit this test Press the CANCEL button twice to exit Diagnostics Error 99 Figure D 7 dIAg 3 Diagnostic Code 4 RAM Test To enter this test enter diagnostics and press the 4 button on the keypa...

Страница 60: ...dle on the dispenser The CPU reads the pump handle switch and writes the status of the handle to the display When the handle is off the display appears as in figure D 9a When a handle is turned on an...

Страница 61: ...NTER to advance to the next counter Communications Failure Counter This code is used to investigate intermittent problems with communications The counters keep track of the number of times a communica...

Страница 62: ...bQtOt 1 Message timeout from Side 1 Modbus device 6 14 bQtOt 2 Message timeout from Side 2 Modbus device 6 15 F1 Error code reported by the side 1 meter the last time a critical error occurred 6 16 F2...

Страница 63: ...he switches for the product buttons During this test the dispenser emits a tone when each product key is pressed The name of the button appears in the top line of the display If no tone is heard the b...

Страница 64: ...d the next logged transition is displayed When all logged transitions have been viewed the display flashes the message shown in figure D 12c Press the CANCEL button to exit this test Press the CANCEL...

Страница 65: ...onds The main display will display Hub Good and both temperature and pressure readings if all tests pass Figure D 12d If a test fails the following will display J2 FAIL Dispenser could not enter diagn...

Страница 66: ...t and damage electronic components Keep the dispenser clean and protected It will keep a new pump appearance longer To clean painted surfaces follow this procedure 1 Wash the dispenser in a solution o...

Страница 67: ...lated Literature Part No Description 119639 LNG Series Installation Manual 120150 Shell LNG CNG Series Operators Manual 120149 Shell LNG Series Service Manual 120151 LNG Series Part Manual 120149 CNG...

Страница 68: ...68 123919 Rev C 5 17 18...

Страница 69: ...69 123919 Rev C 5 17 18...

Страница 70: ...70 123919 Rev C 5 17 18...

Страница 71: ...71 123919 Rev C 5 17 18 Page Intentionally Left Blank...