![Beninca BULL 17 OMAI Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/beninca/bull-17-omai/bull-17-omai_manual_2732994028.webp)
28
16) ERROR MESSAGES
Some messages that are displayed in the event of malfunctions are shown hereunder:
err
Error N.O inputs (autoset)
If the error occurs during self-learning, check the PP/PED/OPEN/CLOSE inputs.
Err1
STOP error (autoset)
STOP intervention during the autoset.
Err2
Error, photocells (Autotest)
PHOTO/PHOTC intervention during the autoset.
Err4
Error, sensitive edge (autoset)
BAR intervention during autoset.
Err5
Error, phototest
Check the operation and correct connection of the photocells.
amp
Triggering of the amperometric sensor
An obstacle or a point of friction has caused the triggering of the amperometric sensor. Remove
the obstacle or check the door stroke.
F01
The brake connected absorbs too much.
F02
Short circuit on the engine. Check the impedance of the windings and the insulation between
each phase of the motor and the ground.
F04
At power-on the bus voltage is not within the specifications. Check the supply voltage, or the
correct selection of the engine according to the menu Mot.
F05
Over temperature detected in the unit.
F06
Instantaneous current threshold exceeded. Unlock the engine and check that the pinion is free
to turn. If necessary, contact technical assistance.
F07
Instantaneous current threshold exceeded. Unlock the engine and verify that there are no
excessive loads (difficulty moving) along the entire travel of the gate. If necessary, contact
technical assistance.
F08
Exceeded maximum allowed voltage on the power bus. Check the supply voltage. Cary out the
following actions in the order indicated:
1. Increase TDEC and TSMO/TSMC parameters, check intermediate stops with STOP/PP/PHOT/
BAR commands, if the problem recurs, go to the following point:
2. Increase parameter TBR, check intermediate stops with STOP/PP/PHOT/BAR commands, if
the problem recurs go to the following point:
3. Connect braking resistance, check intermediate stops with STOP/PP/PHOT/BAR commands,
if the problem recurs go to the following point:
4. Decrease the parameters FSTO/FSTC, check intermediate stops with STOP/PP/PHOT/BAR commands.
F09
The values set are incorrect and the gate goes past the limit switch.
Act by modifying the following parameters in order:
-
blo
/
blc
(decrease)
-
tsmo
/
tsmc
(increase)
-
sldo
/
sldc
(decrease)
-
fsto
/
fstc
(decrease)
17) DISPLAY LCD
The LCD display can be turned by 180°.
-
Cut off mains power supply
-
Press PGM
-
While keeping PGM pressed, reset the mains power supply
-
Keep PGM pressed (around 5 sec) until the software version appears, turned by 180°.
Normally proceed with programming.
18) DIAGNOSTICS
In the event of operating anomalies the status of all inputs (stop command and safety) can be displayed. One segment of the display is linked to each
input. In the event of failure it switches on according to the following scheme.
PHOTO
SWC
STOP
SWO
PHOTC
BAR
P.P.
PED
OPEN
CLOSE
LD1 LED: Mains power present.
LD2 LED: P 5V
PHOTO: PHOT1/TST1
PHOTC: PHOT2/TST2
F4: Power supply line protection fuse 15AT.
Содержание BULL 17 OMAI
Страница 2: ...2 A B 1 204 245 316 398 307 213 398 34mm BULL PI Optional 40 3 1 8 2 0 4 7 0 1 8 0 2 3 B F T 4 ...
Страница 3: ...3 V R 5 MIN 10 mm MAX 20 mm MIN 120 mm MAX 140 mm 6 7 R D R D ...
Страница 5: ...5 12 13 14 C L 7 4 1 2 3 POWER 2 x 1 5 RG 58 5 4 x 0 25 4 6 5 2 x 0 25 3 x 0 25 15 BAR ...
Страница 79: ...79 ...
Страница 80: ...AUTOMATISMI BENINCÀ SpA Via Capitello 45 36066 Sandrigo VI Tel 0444 751030 r a Fax 0444 759728 ...