16
STEP 8
(Installing the Safeties and Safety Cable)
1. Install safety weldments on to each respective post.
(See Fig 8.1 - 8.3)
2. From the Off Side post insert the non-looped end of the
safety cable through the hole located to the right of the Off
Side safety weldment. (See Fig 8.4)
DO NOT RUN POWER UNIT WITHOUT OIL. DAMAGE TO POWER UNIT PUMP CAN OCCUR.
THE POWER UNIT MUST BE KEPT DRY. DAMAGE TO POWER UNIT CAUSED BY WATER OR OTHER
LIQUIDS SUCH AS DETERGENTS, ACID ETC., IS NOT COVERED UNDER WARRANTY.
OPERATE LIFT ONLY BETWEEN TEMPERATURES OF 41 °- 104° F.
IMPROPER ELECTRICAL HOOK-UP CAN DAMAGE MOTOR AND WILL NOT BE COVERED UNDER WARRANTY.
MOTOR CAN NOT RUN ON 50HZ WITHOUT A PHYSICAL CHANGE IN THE MOTOR.
USE A SEPARATE CIRCUIT BREAKER FOR EACH POWER UNIT.
PROTECT EACH CIRCUIT WITH TIME DELAY FUSE OR CIRCUIT BREAKER.
FOR 208-230 VOLT, SINGLE PHASE, USE A 25 AMP FUSE.
FOR 208-230 VOLT, THREE PHASE, USE A 20 AMP FUSE.
FOR 380-440 VOLT, THREE PHASE, USE A 15 AMP FUSE.
Fig 8.1
Hairpin
Cotter
Safety
Clevis
Pin
Off Side and Power Side Top Safety
Top Safety
Weldment
Safety
Bar
Insert non-looped
end of safety cable
through hole in
post
Slip looped end
over bottom pin
Fig 8.4
Power Side Bottom Safety
Fig 8.2
Hairpin
Cotter
Power Side
Safety Weldment
Torsion
Spring
Safety
Clevis Pin
Safety
Bar
Safety
Cable
Off Side Bottom Safety
Safety
Clevis Pin
Torsion
Spring
Off Side Safety
Weldment
Hairpin
Cotter
Safety
Bar
Fig 8.3