7
STEP 1
(Selecting Site)
Before installing your new lift, check the following.
1. LIFT LOCATION: Always use architectural plans when
available. Check the layout dimension against the floor plan
requirements making sure that adequate space if available.
2. OVERHEAD OBSTRUCTIONS: The area where the lift
will be located should be free of overhead obstructions such
as heaters, building supports, electrical lines etc.
3. DEFECTIVE FLOOR: Visually inspect the site where
the lift is to be installed and check for cracked or defective
concrete.
4.
OPERATING TEMPERATURE.
Operate lift only
between temperatures of 41° -104° F.
STEP 2
(Floor Requirements)
This lift must be installed on a solid level concrete floor with
no more than 3-degrees of slope. Failure to do so could
cause personal injury or death.
A level floor is suggested for proper use and installation
and level lifting. If a floor is of questionable slope, consider
a survey of the site and/or the possibility of pouring a new
level concrete slab.
t
DO NOT install or use this lift on any asphalt surface
or any surface other than concrete.
t
DO NOT install or use this lift on expansion seams
or on cracked or defective concrete.
t
DO NOT install or use this lift on a second / elevated
floor without first consulting building architect.
CONCRETE SPECIFICATIONS
LIFT MODEL CONCRETE REQUIREMENTS
PL-14000
7” Min. Thickness / 3,000 PSI
PL-14000XL
7” Min. Thickness / 3,000 PSI
PL-18000
7” Min. Thickness / 3,000 PSI
DANGER!
ALL MODELS MUST BE INSTALLED ON 3000 PSI
CONCRETE ONLY CONFORMING TO THE MINIMUM
REQUIREMENTS SHOWN ABOVE. NEW CONCRETE
MUST BE ADEQUATELY CURED FOR A MINIMUM OF 28
DAYS.
IMPORTANT NOTICE
THESE INSTRUCTIONS MUST BE FOLLOWED TO ENSURE PROPER INSTALLATION AND OPERATION OF YOUR LIFT.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS CAN RESULT IN SERIOUS BODILY HARM AND VOID PRODUCT
WARRANTY. MANUFACTURER WILL ASSUME NO LIABILITY FOR LOSS OR DAMAGE OF ANY KIND, EXPRESSED OR
IMPLIED, RESULTING FROM IMPROPER INSTALLATION OR USE OF THIS PRODUCT.
PLEASE READ ENTIRE MANUAL PRIOR TO INSTALLATION
t
Rotary Hammer Drill or Similar
t
3/4” Masonry Bit
t
Hammer
t
4 Foot Level
t
Open-End Wrench Set: SAE/Metric
t
Socket And Ratchet Set: SAE/Metric
t
Hex-Key / Allen Wrench Set
t
Large Crescent Wrench
t
Large Pipe Wrench
t
Crow Bar
t
Chalk Line
t
Medium Phillips Screwdriver
t
Tape Measure: 25 Foot Minimum
t
Needle Nose Pliers
t
Tall Forklift
t
Tall Crane
t
Tall man lift: 18 Foot minimum rise
TOOLS REQUIRED
IMPORTANT NOTE
BendPak lifts are supplied with installation instructions and concrete fasteners meeting the criteria as prescribed by the American
National Standard "Automotive Lifts - Safety Requirements for Construction, Testing, and Validation" ANSI/ALI ALCTV-2011.
Lift buyers are responsible for any special regional structural and/or seismic anchoring requirements specified by any other
agencies and/or codes such as the Uniform Building Code (UBC) and/or International Building Code (IBC).