38
MOTOR WILL NOT RUN
POSSIBLE CAUSE
1. Fuse blown, (5,2,1,3,4)
2. Limit switch burned out, (1,2,3,4)
3. Microswitch burned out, (1,2,3,4)
4. Motor burned out, (1,2,3,4,6)
5. Voltage to motor incorrect, (2,1,8)
REMEDY
INSTRUCTION
1. Check for correct voltage . . . . . . . . . . . . . . . . . . . . . . . . . . .Compare supply voltage with voltage on motor
name tag. Check that the wire is sized correctly.
N.E.C. table 310-12 requires AWG 10 for 25 Amps.
2. Check motor is wired correctly . . . . . . . . . . . . . . . . . . . . . . .Compare wiring of motor to electrical diagram on
drawing.
3. Don’t use extension cords . . . . . . . . . . . . . . . . . . . . . . . . . . According to N.E.C. : “ The size of the conductors…
should be such that the voltage drop would not exceed
3% to the farthest outlet for power…” Do not run motor
at 115 VAC – damage to the motor will occur.
4. Replace with new part . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace with new part.
5. Reset circuit breaker/fuse . . . . . . . . . . . . . . . . . . . . . . . . . .Reset circuit breaker/fuse.
6. Return unit for repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Return unit for repair.
7. See Installation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . .See Installation Manual.
8. Check wall outlet voltage and wiring . . . . . . . . . . . . . . . . . . Make sure unit and wall outlet is wired properly. Motor
must run at 208/230 VAC.
LIFT LOWERS SLOWLY OR NOT AT ALL
POSSIBLE CAUSE
1. Cylinders binding, (1)
2. Release valve clogged, (5,4,2,3)
3. Pressure fitting too long, (6)
REMEDY
INSTRUCTION
1. See Installation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact BendPak Customer Support.
2. Replace with new part . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replace with new part.
3. Return for repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Return for repair.
4. Check oil. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Use clean 10-WT hydraulic oil or Dexron automatic
transmission fluid only. If ATF is contaminated, replace
with clean ATF and clean entire system.
5. Clean release valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wash release valve in solvent and blow out with air.
6. Replace fitting with short thread lead . . . . . . . . . . . . . . . . . . . Replace fitting with short thread lead.
Содержание PL-14000
Страница 25: ...25 ...
Страница 29: ...29 Not provided by BendPak 4450mm lg 2500mm lg 2200mm lg Multiple Unit Hydraulic Hose Routing ...
Страница 35: ...35 ...
Страница 36: ...36 ...
Страница 41: ...41 Grease Port Lubrication Locations Lubricate Once A Week ...
Страница 43: ...43 ...