Technical data IRDH575
94
IRDH575_D00089_05_M_XXEN/01.2020
Conductor sizes (AWG)...................................................................................................................................... 24…12
Degree of Protection, internal components (DIN EN 60529) .................................................................................. IP30
Degree of Protection, terminals (DIN EN 60529)..................................................................................................... IP20
Degree of Protection, in case of door mounting (DIN EN 60529) ........................................................................... IP40
Degree of Protection, in case of mounting into a door with panel sealing (DIN EN 60529).................................. IP42
Type of enclosure: suitable for panel mounting ............................................................................... free from halogen
Flammability class ........................................................................................................................................... UL94 V-0
Software version ............................................................................................................................................ D185 V1.6
Weight ............................................................................................................................................................... ≤ 900 g
Option "W"
Shock resistance acc. to IEC 60068-2-27 (device in operation).................................................................. 30 g/11 ms
Bumping acc. to IEC 60068-2-29 (transport)................................................................................................ 40 g/6 ms
Vibration resistance acc. to IEC 60068-2-6................................................................................... 1.6 mm/10…25 Hz
.............................................................................................................................................................. 4 g/25…150 Hz
Ambient temperature, during operation ........................................................................................... -25 °C…+70 °C
Ambient temperature, during operation .......................> 55 °C no continuous insulation fault location with 50 mA
Storage temperature range ................................................................................................................ -40 °C…+85 °C