7
INSTALLATION TYPE C
These diagrams detail the installaon of the appliance into a Pre Cast Flue where a
900 PRECAST MANTEL
is being fiPed
For details on
900 PRECAST MANTEL
crical dimensions see page 9.
The
900 PRECAST SPACER KIT
is used to create an
interface between the precast flue and the
900 FIXING
PLATE
. Fit the hearth and firmly aPach the PRECAST
SPACER to the wall. See further details on page 12.
Using mortar or fondue around the inside edge of the
SPACER/FLUE should be sealed and fixed into place as if it
were a marble back panel. It is important that no leakage
should occur.
For minimum hearth requirements see page 9.
The
900 FIXING PLATE
is then screwed to the 900
PRECAST SPACER with the screws provided. Using fire
cement or similar around the inside edge of the joint
between the
900 FIXING PLATE
and the
900 PRECAST
SPACER
. Furthermore a suitable high temperature masc
should be used to further seal around the outside edge of
the
900 FIXING PLATE
and the wall. See further details
on page 13
It is extremely important that both the
900 PRECAST
SPACER
and the
900 FIXING PLATE
are sealed to the flue
as essenally a complete fireplace opening. Check the
integrity of the spacer and fixing plate installaon before
proceeding.
The TYPE C INSTALLATION is completed by installing the
900 PRECAST MANTEL
to the wall securely. The mantel
should be centred around the
900 FIXING PLATE
.
The crical dimensions of the
900 PRECAST MANTEL
are
detailed on page 9. These crical dimensions ensure that
the front trim plate of the fire and the front face of the
mantel are aligned.
The front trim plate of the appliance is fully adjustable
with four independent magnets. These magnets can be
screwed in or out to posion the front trim plate
correctly. This adjustment is provided as there may be
some variaon in the wall flatness and level.
See page 17 for full details regarding front trim
installaon and adjustment.
Ensure the hearth is set level before con1nuing with
the installa1on. Failure to install a level hearth could
affect the installa1on of the mantel and appliance.