Conveyor Belt Scale
Product Manual
D. Terminal Board with 110 / 240 AC Power Supply
All power wiring must conform to local and national electrical codes.
Always disconnect power before servicing the integrator.
The AC Power supply is installed below the Sensor Board. It converts 110/240 AC to 24 VDC.
Ethernet Port
Power Over Ethernet 1.5 A Fuse
Only install this fuse when using
a wireless transmitter!
110 AC - To Power Supply
LINE
– BLACK
NEUTRAL - WHITE
EARTH GROUND
– GREEN
The user must supply a minimum
16-gauge 3 wire power cord.
Connect to a properly grounded
receptacle that is rated for at least
15 Amps at 110 VAC.
24 VDC
From Power Supply
GND = BLACK
+24V = RED
6 A Fuse
NOTE FOR GENERATOR POWER
A generator may produce unstable power during the startup or shutdown sequence.
The integrator is sensitive to power fluctuations and should be disconnected at startup and
shutdown to prevent data loss. Use a breaker or simply unplug the power cord from the
outlet until the generator is fully powered up.
Ferrite Bead Installation
Each scale includes a
ferrite bead to meet
CE emission requirements.
Run all AC wires through
it as shown to the right.