I.
String-Line Idlers to level the Weighbridge:
This is an extremely important step in the insta llation process.
▪
The empty belt must rest uniformly on all idlers within the weighbridge.
▪
Use a minimum of three strings to align all 5 or 6 weighbridge idlers.
▪
Shim idlers if necessary to bring them into alignment.
▪
Use the 3/8-16 leveling bolts to adjust the scale idler height
▪
Tighten U-bolts evenly so pipes remain parallel and oval clearance
around bottom pipe is maintained.
▪
Tighten the jam nuts against the leveling plate to lock the pipes in place.