Phone: (815) 625-5573
beltwayscales.com
Page 16 of 44
Conveyor Belt Scale
Product Manual
J.
Install Hose Clamps:
▪
Install the hose clamps on the outside of the load cell
assembly.
▪
Leave clearance so the clamps don
’t bind between the
pipe and load cell bracket.
▪
Rotate the screw barrels away from the gaps between
the hanger brackets and the pipes.
K.
Install Speed Sensor Assembly
▪
The standard speed sensor assembly may hang
from either pipe. It must point downhill.
▪
The wheel must ride smoothly on the belt.
▪
Avoid installing it near return idlers that may cause the
wheel to bounce.
▪
A small amount of weight may be added to the speed
wheel arm to hold the wheel firmly on the belt.
▪
Use two hose clamps to retain the mounting arm .
▪
Secure the cable to the arm with cable ties. Route the
cables carefully along the conveyor frame so they are
protected from falling debris and pinch points.
L.
Optional Angle Sensor
Any conveyor that frequently changes angle must have an angle sensor installed.
▪
Mount the Angle Sensor directly on the conveyor frame.
▪
Mount in the direction of the head pulley.
▪
Reference the UP arrow indicator on the sensor.
Caution: Excessive vibration
will interfere with Angle Sensor
performance.
Hose Clamps