B. Setup Wizard
The Setup Wizard is a step by step guide for the the initial setup of the Integrator.
Use the following page to record important values before starting the Setup Wizard.
▪
Number of weigh idlers
(1 for single idler scale and 2 for dual idler scale)
▪
Load cell capacity found on Load cell assembly label
(45 kg, 100 kg, 200kg, etc. one box will be punched out)
▪
Idler spacing distance (Measure as shown below)
Single Idler Scale:
Distance A Distance B
Dual Idler Scale:
Distance A Distance B Distance C
▪
Conveyor Angle if an automatic angle sensor is not used.
Note: If the conveyor angle is not known, leave the angle at the default of 12 degrees.
▪
Pulley diameter if using shaft mount speed sensor instead of the wheel speed sensor.