www.tsicustomerservice.com
A474
33
Operation
This fireplace is a zero clearance design. No combustibles can be placed on the top surface of the fireplace.
Combustibles may be installed to the edge of the unit. Insulation and vapor barrier should be placed a minimum of 2 in. from the unit.
Build the framing according to the specifications shown in the below table & figure 1.
WIRING REQUIREMENTS
Use appropriate wire to meet local and national electrical codes for rated power consumption. All wire gauges should be 12 gauge solid
wires with a dedicated 15 amp breaker for 120 volts.
Installation - Built In Construction
Modelo
A
B
C
D
E
F
G
H
I
J
K
L
36HF320FGT
32.8″
18.6″
5.1″
36″
19.7″
5.55″
31.8″
18″
3.39″
42.6″
30.1″
30.1″
48HF320FGT
43.3″
18.6″
5.1″
48″
19.7″
5.55″
42.3″
18″
3.39″
53.5″
37.8″
37.8″