Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for example, the
inside of the cupboard door so it is clearly visible for any service technician.
SETTING THE GAS PRESSURE:
Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas).
For the Model BG604G/A(-F)
, light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00 kPa. Turn the two burners off
and on again and recheck the pressure is same as set previously or adjust as required.
For all the other models,
light all burners on and adjust test point pressure to 1.00 kPa. Turn burners off and on again and recheck the
pressure is same as set previously or adjust as required.
TEST FOR CORRECT OPERATION:
After installation and adjusting burner pressure using test point, each burner ignition and operation must be
tested individually and with all burners operating. This testing must be done by the installer before leaving.
ADJUSTING THE BURNER MINIMUM FLAME HEIGHT:
NOTE: This adjustment can only be performed by the installer or an authorised service personnel.
The minimum burner flame is factory adjusted for the gas type stated on the gas type label adjacent to the gas
connection and should not require adjustment. Adjustment may be required if the hotplate has been converted
from Natural gas to Universal LPG or vice versa.
GAS CONVERSION INSTRUCTIONS:
The manufacturers servicing instructions detail how authorised personnel may convert the hotplate from Natural
gas to Universal LPG or from Universal LPG to Natural gas. Contact the manufacturer or agent as required.
NATURAL GAS
UNIVERSAL LPG
Model
BDG604G/A(-F)
Injector Dia(mm)
MJ/h
Test point kPa
Injector Dia(mm)
MJ/h
Test point kPa
Auxiliary
0.9
4
1
0.55
3.2
2.75
Semi rapid x2
1.1
6
1
0.7
5.5
2.75
Wok
1.7
12.5
1
0.98
10.8
2.75
TOTAL NHGC
28.5
25
NATURAL GAS
UNIVERSAL LPG
Model
BDG302WG/A(-F)
Injector Dia(mm)
MJ/h
Test point kPa
Injector Dia(mm)
MJ/h
Test point kPa
Semi rapid
1.1
6
1
0.7
5.5
2.75
Wok
1.7
12.5
1
0.98
10.8
2.75
TOTAL NHGC
18.5
16.3
NATURAL GAS
UNIVERSAL LPG
Model
BDG302RG/A(-F)
Injector Dia(mm)
MJ/h
Test point kPa
Injector Dia(mm)
MJ/h
Test point kPa
Semi rapid
1.1
6
1
0.7
5.5
2.75
Rapid
1.35
9
1
0.9
9
2.75
TOTAL NHGC
15
14.5
NATURAL GAS
UNIVERSAL LPG
Model
BDG301G/A(-F)
Injector Dia(mm)
MJ/h
Test point kPa
Injector Dia(mm)
MJ/h
Test point kPa
Wok
1.7
12.5
1
0.98
10.8
2.75
TOTAL NHGC
12.5
10.8