PRE INSTALLATION INSTRUCTIONS
GENERAL
This ‘direct vent’ gas appliance must be installed by a qualifi ed installer in accordance
with local building codes, or in the absence of local codes, with the current CAN/CSA-
B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code
Z223.1-NFPA 54 when installed in the United States.
This appliance, when installed, must be electrically connected and grounded in
accordance with local codes, or in the absence of local codes, with the current CSA
C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70
when installed in the United States. If you have any queries regarding the installation,
please consult your local gas company.
IMPORTANT:
Before beginning the installation, check that the details on the rating
plate correspond to the gas type and pressure to which the appliance
will be connected.
WARNING:
Due to high temperatures, the appliance should be
located out of traffi c and away from furniture and draperies.
The appliance is supplied with a “Line Fire” double burner. This burner has a specifi c
fl ame image which is defi ned by the perforation pattern in the burner cover.
See Chapter “DIAGRAM ELECTRICITY AND GAS” and the Operating Manual.
The appliance is factory set to the correct nominal heat input. The pilot light is set to the
correct level of consumption.
The appliance will be delivered from the factory with a 5⅛" x 7⅞" concentric connection
for extracting the fl ue gases and supply of combustion air.
It is possible to install the appliance with either a wall or roof outlet. The roof connection
must be carried out using a Bellfi res adapter (5⅛" x 7⅞" to 5" x 8") together with a
reducer (5" x 8" to 4" x 6⅝") or using a Bellfi res adapter (5⅛" x 7⅞" to 4" x 6⅝"), and
the concentric fl ue system 4" x 6⅝". The fumes are exhausted naturally to the outside
environment through the inner 4" pipe whereas the combustion air supply passes
between the 4" and 6⅝" pipes.
The wall connection must be carried out using a Bellfi res adapter (5⅛" x 7⅞" to 5" x 8")
and the concentric fl ue system 5" x 8". The fl ue gases are evacuated outside by means
of natural draft through the internal pipe of 5", whereas the combustion air is supplied
between the pipes of 5" and 8".
The appliance can be installed in a completely sealed or mechanically ventilated house
without extra ventilation and/or fume extraction.