44
Bell
fi res
Installation instructions
Gas connection:
Built-in appliance: Operation (gas regulator block (and receiver))
outside
the appliance
(in the operating unit):
The gas connection ⅜" NPT is situated where the operating- unit
is built in near to the appliance.
Wall-mounted appliance: Operation (gas regulator block (and receiver))
under
the
appliance:
The gas connection ⅜" NPT is situated on the underside
of the appliance.
GAS LINE INSTALLATION
Figure 18: Operating unit
BUILT-IN APPLIANCE - Gas connection operating unit
The appliance is supplied with a built-in operating unit.
Frame with
door (white)
Operating unit
9.7”
1
2
.4
”
WARNING:
Connection of the appliance to gas supply must be performed by a qualifi ed
installer, service agency or the gas supplier. Follow the local codes.
IMPORTANT:
During gas connection, take care not to twist the gas regulator block.
Make sure that both the gas regulator block and the supply pipes are
not subjected to stresses.