54
Bell
fi res
Installation instructions
BUILDING IN / HANGING OF THE APPLIANCE
(*) Made of a non-combustible insulation plate/board, according the material
specifi cations in the Chapter: CLEARANCES.
IMPORTANT:
Install the appliance and the insulation plate/board according
to the Chapter: CLEARANCES.
Positioning the cove - WALL-MOUNTED APPLIANCE
• Only non-fl ammable materials are permitted for the cove.
• Ventilate the cove over the appliance by fi tting with vents
at the top of the cove.
• Ensure that the cove does not rest on the appliance.
If necessary, use a mantle iron. (accessorie).
Cove - Top
Cove - Bottom
Cove bottom
• min. 20 cm high
• max. 30 cm high
due to the build-up
of heat
Never
seal the bottom
of the cove bottom.
Leave open!
Outlet opening (grate) (2x)
natural convection air
minimal 2x 23 in
2
(2x 150 cm
2
)
False back wall (*)
False ceiling (*)