Bellcall Digital Door Entry System
PD-083 Issue 3A
Installation and Operating Manual
Page 18 of 46
Programming the Panel – BSD-DIG
The BSD-DIG is programmed from the panel for all settings.
Security
It is strongly recommended that the Panel Security Code (PSEC) be changed from its
factory setting to prevent unauthorised access. Record the new number carefully as it
cannot be easily changed if lost. It is also recommended that the Phone Programming
Code (PPRG), Coded Access Code (ACOD) and Trades Access Code (TCOD) are all
changed from default even if not used.
To access panel programming without the code requires physical access to the controller
PCB, borrow a jumper from say video gain (remember the setting) and place it on the 5 pin
programming header between pins 1 & 2. Now pressing the test button will enter panel
programming for 30S when the panel security code can be read or set.
When the
programming is finished replace the jumper back to its original location.
Panel Programming
To use Panel Programming Mode :-
First type the Panel Security Code (initially 3434) followed by the
call
button.
The display will show the first programmable parameter (ACOD), and then alternating
at 1S intervals will be the data and the parameter name.
Press the
door
button to step down through the programmable parameters.
Press the
reception
button to step up through the programmable parameters.
The list rolls over bottom to top and vice versa.
To change a numeric parameter simply type a new 1-4-digit value and then press
call
.
To change other values simply press
call
to choose the next value.
To exit Panel Program Mode press
cancel
.
If no button is pressed for 30S then programming mode will auto-cancel.
Code
Default Access Description
ACOD
1234
Coded access code – must be 4 digits
TCOD
6789
Trade access code – must be 4 digits
LTIM
0003
Lock Time: 1-99 seconds
LOCK
Secr
Lock Type: Secr (fail secure), Safe (fail safe)
CAM2
No
Camera 2: No (absent), Yes (present)
TRAD
0005
Trade Function: 0-9 – see table
DMON
Cwo
Door Monitor Polarity: Cwo, Owo
RECP
9898
Reception / Porter phone number
PSEC
3434
Panel security code
PPRG
1212
Phone programming security code
RING
0015
Ring Time – see table
TALK
0015
Talk Time – see table
TONE
Both
Ring and Lock Buzz-Tone enable, 4 settings
CANC
Yes
Allow
Cancel
button to terminate Call
BCAL
No
Bellcall BCP1 compatibility mode
12A?
No
Allows user entry of 12A to call BSC4 output 13