Bellcall Digital Door Entry System
PD-083 Issue 3A
Installation and Operating Manual
Page 16 of 46
Programming the Panel – BCP1
The BCP1 is programmed from the panel for all settings.
Security
It is strongly recommended that the Panel Security Code (PSEC) be changed from its
factory setting to prevent unauthorised access. Record the new number carefully as it
cannot be easily changed if lost. It is also recommended that the Phone Programming
Code (PPRG), and Coded Access Code (ACOD) are all changed from default even if not
used.
To access panel programming without the code requires physical access to the controller.
Now pressing the test button will enter panel programming for 10S when the panel security
code can be read or set..
Panel Programming
To use Panel Programming Mode :-
firstly type the Panel Security Code (initially 3434) followed by the
call
button.
The display will show the first programmable parameter (MODE).
Press the
door
button to alternate between the current value of the parameter and the
name of the parameter.
Press the
porter
button to step through the programmable parameters:
To change a parameter simply type a new 4-digit value and then press
call
.
To exit Panel Program Mode press
cancel
.
If no button is pressed for 10S then programming mode will auto-cancel.
Code
Action Default Action Description
MODE
5003
Multi-Function (See Below)
CODE
1234
Access Code
PORT
0101
Reception/Porter’s Phone Number
PSEC
3434
Panel Security Code
TSEC
1212
Phone Security Code – Program Phone