Bellcall Digital Door Entry System
PD-083 Issue 3A
Installation and Operating Manual
Page 17 of 46
MODE parameter
Enter a 4-digit number ABCD, Where:-
A is the Trade Mode 0-9 (see table).
B is the lock type; 0= fail secure, 1=fail-safe.
C is unused, set to 0.
D is the lock duration 0-9 secs.
Default 5003; Trade Mode 5, Fail-Secure Lock, Lock Duration 3 seconds
A Trade Mode:
Code = Pressing the
door
button prompts for the access code to open the door.
Door = Pressing the
door
button opens the door.
None = No function pressing the
door
button is ignored.
E.g. 5105; Trade Mode 5, Fail-Safe Lock, Lock Duration 5 seconds
Trade Mode Setting
Time
Input
0
1
2
3
4
5
6
7
8
9
Open None Door Code None Door
Code
None Door Code None
Closed None None None Door Door
Door
Code Code Code None
CODE – Access Code
Code to open the door. Valid whenever the display indicates CODE. The Trades mode
needs to be set to Code as per the table above.
The default is 1234 and it is
recommended that this is changed for security.
Letters cannot be used in this code, and 4 digits must be used, leading 0 is OK.
PORT – Porter Phone Address
The
porter
button is used to call a porter or reception desk or similar. The number is that
of the called phone. The default is 101 which is unlikely to be used by a flat.
PSEC – Panel Security Key
The security key is required to gain access to panel programming.
The code is entered then pressing the
call
button, the default is 3434 and it is
recommended that this be changed for security.
This code can contain letters and numbers for added security.
TSEC – Phone Programming Security Key
The phone programming security key is required to gain access to flat number
programming of telephones.
The default is 1212 and it is recommended that this be
changed for security.
This code can contain letters and numbers for added security.