Copiscan 8000 Spectrum Operator Manual
81
Scanner Configuration Errors
Error Condition
Message Displayed
Explanation/Remedy
Binary EGSA in Color
Scanner
“EGSA not color capable” The EGSA reports binary-only
capability, but the scanner is
color.
Please call technical support at
1-800-SCAN-495
.
Interface Slot Error
“Bad/missing EGSA board” The power up self test reports
that the EGSA board is missing
from interface slot.
Please call technical support at
1-800-SCAN-495
.
Interface Not
Responding Error
“EGSA board init failed”
The EGSA did not respond with
the proper initialization sequence
within the allowable timeout
period after power up.
Please call technical support at
1-800-SCAN-495
.
Feeder Error
“Bad/missing feeder”
The feeder is not connected or is
not responding.
Please call technical support at
1-800-SCAN-495
.
Illumination Errors
Error Condition
Message Displayed
Explanation/Remedy
Front Lamps Low Error
“Low front lamp level
” The front lamp sensor
indicates that front lamps
are too low for proper
scanning. Either the lamps
are old and need to be
replaced, one lamp is out, or
there is a sensor problem.
Check front lamps and
sensor and replace lamps if
necessary (Section 6.11).
Back Lamps Low Error
“Low back lamp level
” The back lamp sensor
indicates that back lamps
are too low for proper
scanning. Either the lamps