Installation MACH104-PoEP
Release 06 11/2013
31
3
Basic set-up
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the application HiDiscovery or
Industrial HiVision
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP Option 82
Auto Configuration Adapter
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual on the CD/DVD.
3.1
Default settings
IP address: The device looks for the IP address using DHCP
Management password:
user, password: public (read only)
admin, password: private (read and write)
V.24 data rate: 9,600 Baud
Ring redundancy: off
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s full duplex
All other ports: autonegotiation
Redundancy manager switched off
(DIP switch RM and Stand-by: ON)
WARNING
UNINTENTIONAL OPERATION IN DEVICE
Two or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.