Note:
You will find the order number for the terminal cable, which is ordered
separately, in the Technical Data chapter
(see on page 35 “Technical data”)
.
1.8.2
USB interface
The USB socket provides an interface for the local connection of an
AutoConfiguration Adapter. It is used for saving/loading the configuration and
for loading the software.
1.9
Signal contact
The signal contact is a potential-free relay contact.
The device allows you to perform remote diagnosis via the signal contact. In
the process, the device signals events such as a line interruption. When an
event occurs, the device opens the relay contact and interrupts the closed
circuit. The management setting specifies which events switch a contact.
You can also use the management to switch the signal contact manually and
thus control external devices.
Figure
Pin
Operation
1
VCC (VBus)
2
−
Data
3
+ Data
4
Ground (GND)
Table 11: Pin assignment of the USB interface
1 2
4
3