MACH 100
Release 04 07/10
31
Figure 20: Connecting the supply voltage via the 3-pin terminal block
1 - Fastening screw for functional earth
2 - Fastening screw for supply voltage: -
3 - Fastening screw for supply voltage: +
4 - Connection for functional earth
5 - Connection for supply voltage: -
6 - Connection for supply voltage: +
Note:
Relevant for North America:
The tightening torque of the terminal block screws is 3 lb in. (0.34 Nm).
Note:
Make sure the following requirements are met:
Supply line length < 3 m
Supply line cross section is suitable for 5 A
Pull the terminal block(s) off the switch and connect the voltage supply
lines as follows:
First connect the protective conductor to the protective conductor
terminal.
Connect the PoE voltage to the 3-pin terminal block.
2.1.8
Startup procedure
By connecting the voltage supply via the voltage supply socket(s), you start
the operation of the device.
2.1.9
Connecting the data lines
10/100 Mbit/s twisted pair connection
These connections are RJ45 sockets.
10/100 Mbit/s TP ports enable the connection of terminal devices or
independent network segments according to the IEEE 802.3 10BASE-T/
100BASE-TX standard.
These ports support:
Autonegotiation
Autopolarity
Autocrossing (if autonegotiation is activated)
3
2
1
6
5
4