MACH 100

Release 04 07/10

Technical Support

[email protected]

User Manual

Installation
Industrial ETHERNET Workgroup Switch 
MACH 100 Family

MACH 102-8TP-F

MACH 102-24TP-F

MACH 102-8TP + M1-8TP-RJ45 + M1-8MM-SXC

MACH 102-8TP + M1-8SM-SXC + M1-8SFP

Содержание HIRSCHMANN M1-8MM-SXC

Страница 1: ...7 10 Technical Support HAC Support Belden com User Manual Installation Industrial ETHERNET Workgroup Switch MACH 100 Family MACH 102 8TP F MACH 102 24TP F MACH 102 8TP M1 8TP RJ45 M1 8MM SXC MACH 102 8TP M1 8SM SXC M1 8SFP ...

Страница 2: ...eatures described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the informa...

Страница 3: ...mbly and start up 21 2 1 Installing the device 21 2 1 1 Unpacking and checking 21 2 1 2 Installing the media modules 21 2 1 3 Installing the SFP modules 23 2 1 4 FAULT signal contact 24 2 1 5 Dimension drawings 25 2 1 6 Installing the device and grounding 25 2 1 7 Supply voltage 28 2 1 8 Startup procedure 31 2 1 9 Connecting the data lines 31 2 2 Display elements 34 2 3 Basic set up 36 2 4 Disasse...

Страница 4: ...does not contain any service components Internal fuses are only triggered if there is a fault in the device If the device is not functioning correctly or if it is damaged switch off the voltage supply and return the device to the plant for inspection Only switch on the device when the housing is closed Only use connection cables that are permitted for the specified temperature range Relevant for N...

Страница 5: ... Only technicians authorized by the manufacturer are permitted to open the housing The device is grounded via the voltage supply socket Make sure that the electrical installation meets local or nationally applicable safety regulations The ventilation slots must not be covered so as to ensure free air circulation The clearance to the ventilation slots of the housing must be at least 10 cm 3 94 in W...

Страница 6: ...ctricity is used to operate this equipment Comply with every detail of the safety requirements specified in the operating instructions regarding the voltages to apply see page 4 Warning Only trained service personnel are authorized to plug the M1 8TP RJ45 PoE media module into the basic device or remove from the basic device Non observance of these safety instructions can therefore cause material ...

Страница 7: ...sed Make sure you adhere to the following protection measures for electrostatically endangered assemblies Create electrical equipotential bonding between yourself and your environment e g using a wristband which you clamp to the basic device knurled screw of an interface card When the power supply cable is connected the basic device is grounded via the power supply connection Only now do you take ...

Страница 8: ...asures The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values FCC note This device complies with part 15 of the FCC rules Operation is subject to the following two conditions This device may not cause harmful interference and this device must accept any interference received including interference that may cause undesired ope...

Страница 9: ...MACH 100 Release 04 07 10 9 Recycling note After usage this product must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state and country ...

Страница 10: ... manual The Network Management Software HiVision Industrial HiVision provides you with additional options for smooth configuration and monitoring Configuration of multiple devices simultaneously Graphical interface with network layouts Auto topology discovery Event log Event handling Client Server structure Browser interface ActiveX control for SCADA integration SNMP OPC gateway Legend The symbols...

Страница 11: ...ey meet the relevant industry standards provide very high operational reliability even under extreme conditions and also long term reliability and flexibility The devices work without a fan If desired the voltage supply can be redundant depending on the device variant The basic devices are suitable for mounting on the 19 rack and for wall mounting The HIPER Ring redundancy concept enables you to q...

Страница 12: ...MACH 100 devices are managed The Gigabit ETHERNET combo ports can be connected optically or with TX of the basic devices are suitable for the connection of terminal devices or network segments according to the standards IEEE 802 3 100 1000BASE FX SFP slot and IEEE 802 3 1000BASE TX 100BASE TX 10BASE T RJ45 socket A plugged SFP module switches the TX port off The Fast ETHERNET ports 10 100 Mbit s o...

Страница 13: ... 8TP RJ45 PoE The MACH 102 8TP and MACH 102 8TP R devices from the Industrial ETHERNET MACH100 family are modular switches The devices consist of a basic switch device and depending on the device variant pluggable media modules for additional ports Up to two pluggable media modules each provide an additional 8 Fast Ethernet interfaces They differ as to the media type for connecting segments For th...

Страница 14: ...RNET combo ports 8 Fast ETHERNET ports MACH 102 8TP FR The power supply is connected redundantly Gigabit ETHERNET GE ports 1 and 2 combo ports Fast ETHERNET FE ports 1 to 8 Fast ETHERNET FE ports 9 to 24 2 slots for media modules at your option 100 1000 Mbit s fiber optic SFP slots Alternatively connectable 10 100 1000 Mbit s twisted pair RJ45 connectors 8 twisted pair TX RJ45 10 100 Mbit s 8 twis...

Страница 15: ... USB interface 5 V 24 access for external management 6 See following table column 1 7 See following table column 2 Gigabit ETHERNET GE ports 1 and 2 combo ports Fast ETHERNET FE ports 1 to 8 100 1000 Mbit s fiber optic SFP slots Alternatively connectable 10 100 1000 Mbit s twisted pair RJ45 connectors 8 twisted pair TX RJ45 10 100 Mbit s LS DA USB V 24 MACH 1000 2 1 LS DA 3 4 9 10 P StandBy RM FAU...

Страница 16: ...dia module in its place the MACH 100 performs a warm start The media modules each have 8 Fast ETHERNET interfaces and differ as to their media type The different interfaces of the MACH 100 media modules provide you with the following interface specific functions Specific functions of TP TX interface Link Control Auto Polarity Exchange Autonegotiation Autocrossing device may be connected with a cro...

Страница 17: ...pport autocrossing Figure 5 Media module M1 8TP RJ45 Media module M1 8TP RJ45 PoE Note The use of the M1 8TP RJ45 PoE module will void the UL certification of the basic module Observe the instructions given in the information sheet of the media module M1 8TP RJ45 PoE The M1 8TP RJ45 PoE media module supports Power over ETHERNET PoE It has 8 10 100 Mbit s TP PoE ports These connections are RJ45 soc...

Страница 18: ...2 up to class 0 The PoE voltage is input via the wire pairs transmitting the signal phantom voltage The individual ports joint PoE voltage are not electrically insulated from each other The following conditions are met in accordance with IEEE 802 3af Endpoint PSE Alternative A The pin assignment corresponds to MDI X Figure 6 Media module M1 8TP RJ45 PoE Media module M1 8MM SC The M1 8MM SC media m...

Страница 19: ...ndard The optical ports are configured in 100 Mbit s Fullduplex FDX and support FEFI They are designed as SFP slots for the Hirschmann SFP module types M FAST SFP see page 44 Accessories Figure 9 Media module M1 8SFP 1 1 3 SFP modules SFP modules are optical transceivers Fast ETHERNET and Gigabit ETHERNET SFP modules see page 44 Accessories SFP stands for Small Form factor Pluggable and is also fr...

Страница 20: ... nm Singlemode 25 km LC M FAST SFP SM LC 1310 nm Singlemode 25 65 km LC M FAST SFP LH LC 1550 nm Longhaul 40 104 km LC Gigabit ETHERNET SFP modules LC M SFP MX LC 1310 nm Multimode 2 km LC M SFP SX LC 850 nm Multimode 0 55 km LC M SFP LX LC 1330 nm Multimode 1330 nm Singlemode 0 55 km 20 km LC LC M SFP LX LC 1310 nm Singlemode 14 42 km LC M SFP LH LC Longhaul 8 72 km LC M SFP LH LC Longhaul 60 120...

Страница 21: ...tup Connecting the data lines 2 1 Installing the device 2 1 1 Unpacking and checking Check that the contents of the package are complete see page 44 Scope of delivery Check the individual parts for transport damage 2 1 2 Installing the media modules Warning Only trained service personnel are authorized to plug the M1 8TP RJ45 PoE media module into the basic device or remove from the basic device W...

Страница 22: ...moving a TX media module and plugging in an FX media module in its place the MACH 100 performs a warm start Figure 10 MACH 100 device equipped with media modules 1 Media module 1 2 Media module 2 To attach a media module first remove the 2 screws on the protective cover of the media module slot and remove the protective cover Plug the media module into the desired slot Fasten the 2 screws at the c...

Страница 23: ...ing an SFP module first remove the protective cap over the socket Push the SFP module with the lock closed into the socket until it latches audibly in place Note Only use Hirschmann SFP modules see page 44 Accessories Figure 12 Installing an SFP module Fast ETHERNET fiberoptic SFP module Gigabit ETHERNET fiberoptic SFP module 1 ...

Страница 24: ...the potential free signal contact relay contact closed circuit The failure of at least one of the two voltage supplies voltage supply 1 or 2 is below the threshold value A continuous malfunction in the device internal supply voltage The defective link status of at least one port The report of the link status can be masked by the Management for each port In the default state link status monitoring ...

Страница 25: ...nal contact on the front of the device using the screw locking Check whether the terminal block is mounted correctly and screwed on 2 1 5 Dimension drawings 2 1 6 Installing the device and grounding The device can be mounted on a flat surface in a 19 standard switch cabinet or on the wall Consider the following criteria when selecting the location for mounting your device The installation location...

Страница 26: ...o the front panel as a conductor Mounting the MACH 100 as a table unit Install the device in line with the criteria listed in Installing the device and grounding Mounting the MACH 100 in a switch cabinet The devices are designed to be mounted in a 19 rack Make sure there is sufficient ventilation If necessary provide a fan for the 19 rack This will prevent the basic devices from overheating Measur...

Страница 27: ...ditional brackets at the back of the switch cabinet see on page 44 Accessories not included in the delivery P 1 LS DA 2 3 4 5 6 7 8 M4 8 TP R J45 LS DA LS DA LS DA LS DA LS DA LS DA LS DA R 1 LS DA 2 3 4 5 6 7 8 LS DA LS DA LS DA LS DA LS DA LS DA LS DA P 1 LS DA 2 3 4 5 6 7 8 1 4 7 2 5 8 3 6 M4 F AST 8SFP P 1 2 3 4 5 6 7 8 1 4 7 2 5 8 3 6 P P1 P2 P3 P4 RM RL1 RL2 FAN RUN L D FDX 1000 AN TP FO RIN...

Страница 28: ...lling the device make sure the ventilation slots remain unobstructed as otherwise the device can overheat and be damaged Figure 17 Vertical mounting on the wall Note The shielding ground of the connectable industrial twisted pair lines is connected to the front panel as a conductor Grounding The device is grounded via the voltage supply socket see fig 18 and see fig 19 2 1 7 Supply voltage The inp...

Страница 29: ...ith redundant supply the standard voltage supply alone supplies the device The redundant voltage supply automatially becomes active if the standard voltage supply fails In the normal case the redundant voltage supply works in stand by mode The supply voltage is electrically isolated from the housing Figure 19 Connections for the MACH 102 8TP R MACH 102 8TP FR and MACH 102 24TP FR on the back of th...

Страница 30: ...ce and the M1 8TP RJ45 PoE media module The PoE voltage is input via the wire pairs transmitting the signal phantom voltage The individual ports joint PoE voltage are not electrically insulated from each other The following values apply to the PoE supply voltage of the module To supply the module with PoE voltage you need an external power supply unit Make sure that the external power supply unit ...

Страница 31: ...ble for 5 A Pull the terminal block s off the switch and connect the voltage supply lines as follows First connect the protective conductor to the protective conductor terminal Connect the PoE voltage to the 3 pin terminal block 2 1 8 Startup procedure By connecting the voltage supply via the voltage supply socket s you start the operation of the device 2 1 9 Connecting the data lines 10 100 Mbit ...

Страница 32: ... lines standards These ports support Autonegotiation Autopolarity Autocrossing if autonegotiation is activated 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode Power over ETHERNET PoE State on delivery autonegotiation activated The socket housing is electrically connected to the front panel The PoE voltage is input via the wire pairs tra...

Страница 33: ... you should adhere to the following recommendations for data cable connections using copper in environments with high electrical interference levels Keep the length of the data cables as short as possible ideally max 3m long You should not use any copper data cables for the data transmission between buildings Power supply and data cables should not run parallel over longer distances and ideally th...

Страница 34: ...ts are only connected with SM ports and MM ports only with MM ports 1 Gbit s F O connection These ports are SFP slots 1 Gbit s F O ports enable the connection of terminal devices or independent network segments according to the IEEE 802 3 1000BASE SX 1000BASE LX standard These ports support Autonegotiation Full duplex mode State on delivery autonegotiation activated Note Make sure that the LH port...

Страница 35: ... MACH 102 24TP FR Supply voltages 1 and 2 are below minimum value RM Ring Manager green yellow LED Glowing green RM function active redundant port disabled Glowing yellow RM function active redundant port enabled Not glowing RM function not active Flashing green Incorrect configuration of the HIPER Ring e g the ring is not connected to the ring port Sb StandBy stand by mode green LED Glowing green...

Страница 36: ...ings of the device can be found in the Basic Configuration user manual on the CD ROM Default settings IP address The device looks for the IP address using DHCP Management password user password public read only admin password private read and write V 24 data rate 9 600 Baud Ring redundancy off Ethernet ports link status is not evaluated signal contact LS data link status one green yellow LED or on...

Страница 37: ...serial interface is provided on the RJ11 socket V 24 interface for the local connection of an external management station VT100 terminal or PC with appropriate terminal emulation or an AutoConfiguration Adapter ACA 11 This enables a connection to the Command Line Interface CLI and the system monitor to be made The socket housing is electrically connected to the front panel of the device The V24 in...

Страница 38: ...ackets on the device Figure 24 Disassembly Deinstalling the media modules Warning Only trained service personnel are authorized to plug the M1 8TP RJ45 PoE media module into the basic device or remove from the basic device Warning Disconnect the PoE voltage supply before removing the M1 8TP RJ45 PoE media module Pin 1 Pin 1 Pin 8 Pin 5 Pin 6 RJ11 DB9 2 3 5 1 2 3 4 5 6 CTS n c TX GND RX RTS MACH 10...

Страница 39: ...rners of the media module Pull the media module out of the slot Fasten the protective cover to the slot using the two screws Disassembling the SFP modules Pull the module out of the socket by means of the opened lock Close the socket with the protective cap Figure 25 Deinstalling an SFP module ...

Страница 40: ...er supply M1 8TP RJ45 PoE for type1 PD Rated voltage Rated current 48 V DC 45 V DC 57 V DC 2 5 A Power supply M1 8TP RJ45 PoE for type2 PD Rated voltage Rated current 54 V DC 51 V DC 57 V DC 2 5 A Overload current protection at input Non replaceable fuse Activation current typ 40 A at 265 V AC and cold start Signal contact Switching current max 1 A SELV Switching voltage max 60 V DC or max 30 V AC...

Страница 41: ...rence EN 55022 Class A Yes FCC 47 CFR Part 15 Class A Yes TP port Length of a twisted pair segment max 100 m 300 ft cat5e cable with 1000BASE T Table 8 TP port 10BASE T 100BASE TX 1000BASE T Product code M FAST SFP Wave length Fiber System attenuatio n Expansion Fiber data MM LC MM 1310 nm 50 125 µm 0 8 dB 0 5 km 1 0 dB km 800 MHz km MM LC MM 1310 nm 62 5 125 µm 0 11 dB 0 4 km 1 0 dB km 500 MHz km...

Страница 42: ...dB km 19 ps nm km Table 10 Fiber port 1000BASE FX SFP fiber optic Gigabit ETHERNET Transceiver MACH 100 Family Description Basic devices MACH102 8TP Basic device MACH 100 family with 2 x Gigabit ETHERNET combo port 8 x Fast ETHERNET TX 2 sockets for media modules for up to 16 additional ports MACH102 8TP R Basic device MACH 100 family with 2 x Gigabit ETHERNET combo port 8 x Fast ETHERNET TX 2 soc...

Страница 43: ... 0 C to 50 C 943 970 301 Fast ETHERNET SFP modules M FAST SFP MM LC 0 W 0 Btu IT h 0 C to 60 C 943 865 001 M FAST SFP MM LC EEC 0 W 0 Btu IT h 40 C to 70 C 943 945 001 M FAST SFP SM LC 0 W 0 Btu IT h 0 C to 60 C 943 866 001 M FAST SFP SM LC EEC 0 W 0 Btu IT h 40 C to 70 C 943 946 001 M FAST SFP SM LC 0 W 0 Btu IT h 0 C to 60 C 943 867 001 M FAST SFP SM LC EEC 0 W 0 Btu IT h 40 C to 70 C 943 947 00...

Страница 44: ... MACH102 8TP F or MACH102 8TP FR 2 combo ports alternatively 100 1000 Mbit s optical SFP slot or 1000 100 10 Mbit s RJ45 socket 8 x 10 100 Mbit s twisted pair RJ45 socket MACH102 24TP F or MACH102 24TP FR 2 combo ports alternatively 100 1000 Mbit s optical SFP slot or 1000 100 10 Mbit s RJ45 socket 24 x 10 100 Mbit s twisted pair RJ45 socket Media modules M1 8TP RJ45 8 x 100 Mbit s twisted pair RJ...

Страница 45: ...apter ACA 21 USB 943 271 001 Terminal cable 943 301 001 2 pin terminal block 50 units 943 845 010 Bracket for fastening the housing 943 943 001 HiVision Network Management software 943 471 100 Industrial HiVision Network Management software operator edition 943 156 xxx OPC Server software HiOPC 943 055 001 3 pin terminal block low voltage interlock 50 pieces 943 845 011 Name EN 61000 6 2 2005 Gene...

Страница 46: ...RFC 2132 DHCP Options RFC 826 ARP RFC 2236 IGMPv2 RFC 951 BOOTP RFC 2239 MAU MIB RFC 1112 IGMPv1 RFC 3411 SNMP Framework RFC 1157 SNMPv3 RFC 3412 SNMP MDP RFC 1155 SMIv1 RFC 3413 SNMP Applications RFC 1213 MIB2 RFC 3414 SNMP USM RFC 1493 Dot1d RFC 3415 SNMP VACM RFC 1542 BOOTP Extensions RFC 2613 SMON RFC 1757 RMON RFC 2674 Dot1p Q IEEE 802 1 D Switching GARP GMRP Spanning Tree IEEE 802 1 D 1998 M...

Страница 47: ...n the long term excellent products alone do not guarantee a successful customer relationship Only comprehensive service makes a difference worldwide In the current global competition scenario the Hirschmann Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation throug...