background image

Installation GREYHOUND Switch

Release 07 10/2020

93

9

Underlying technical standards

The device generally fulfills the technical standards named in their current 
versions.

Name

ATEX (2014/34/EU)

ATEX – Intended use of equipment and protection systems in 
potentially explosive areas.

RCM

Australian Regulatory Compliance Mark (RCM)
Australian Radiocommunications Standard 2008, 
Radiocommunications Act 1992

FCC 47 CFR Part 15

Code of Federal Regulations

DNVGL-CG-0339

Environmental test specification for electrical, electronic and 
programmable equipment and systems. 

ANSI/UL 121201

Nonincendive Electrical Equipment for Use in Class I and II, Division 2 
and Class III, Divisions 1 and 2 Hazardous (Classified) Locations

CAN/CSA C22.2 
No. 213

Non-incendive Electrical Equipment for Use in Class I, Division 2 
Hazardous Locations. 

IEC 60825-1

Laser product safety

IEC 60945

Navigation and wireless communication devices and systems for 
maritime transport - General requirements - Test procedure and 
required test results. 

IEC/EN 61850-3

Communication networks and systems for power utility automation - 
Part 3: General requirements.

IEEE 1613

IEEE Standard Environmental and Testing Requirements for 
Communication Networking Devices in Electric Power Substations

IEEE 802.3

Ethernet

EN 50121-4

Railway applications – EMC – Emission and immunity of the signaling 
and telecommunications apparatus (Rail Trackside)

EN 55032

Electromagnetic compatibility of multimedia equipment – Emission 
Requirements

EN 60950-1

Information technology equipment – Safety – Part 1: General 
requirements

EN 61000-3-2

Electromagnetic compatibility (EMC) – part 3-2: Threshold values – 
threshold values for harmonic currents (device input current 

 16 A per 

conductor)

EN 61000-3-3

Electromagnetic compatibility (EMC) – part 3-3: Threshold values – 
limitation of voltage changes, voltage fluctuations and flickering in 
public low power supply networks for devices with a rated current 

 

16 A per conductor that are not subject to any special connection 
condition

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – 
Immunity for industrial environments

EN 61000-6-4

Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – 
Emitted interference in industrial environments

EN 61131-2

Programmable controllers – Part 2: Equipment requirements and tests

NEMA TS 2

Traffic Controller Assemblies with NTCIP Requirements 
(environmental requirements)

Table 17: List of the technical standards

Содержание Hirschmann GREYHOUND GMM20

Страница 1: ...itch Release 07 10 2020 Technical support https hirschmann support belden com User Manual Installation GREYHOUND Switch GRS1042 GRS1142 GREYHOUND Power supply module GPS1 C GPS1 K GPS3 P GREYHOUND Media module GMM20 30 32 40 42 ...

Страница 2: ...se The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or acc...

Страница 3: ...3 1 GRS1042 27 1 3 2 GRS1142 28 1 3 3 Power supply modules 30 1 3 4 Media modules 31 1 3 5 Port assignments 34 1 4 Power supply 35 1 5 Signal contact 37 1 6 Ethernet ports 37 1 6 1 1 2 5 Gbit s F O port 37 1 6 2 100 1000 Mbit s F O port 38 1 6 3 100 Mbit s F O port 38 1 6 4 10 100 1000 Mbit s twisted pair port 39 1 6 5 Support of PoE 39 1 6 6 Out of band management port 40 1 7 Pin assignments 40 1...

Страница 4: ...ng the terminal blocks 59 2 7 1 Supply voltage 59 2 7 2 Signal contact 64 2 8 Installing an SFP transceiver optional 65 2 9 Operating the device 66 2 10 Connecting data cables 66 2 11 Filling out the inscription label 66 3 Making basic settings 67 3 1 First login Password change 68 4 Monitoring the ambient air temperature 69 5 Maintenance and service 70 6 Disassembly 71 6 1 De installing a power s...

Страница 5: ...020 5 7 1 3 Media modules 77 7 2 Dimension drawings 78 7 3 EMC and immunity 82 7 4 Network range 85 7 5 Power consumption power output 89 8 Scope of delivery order numbers and accessories 90 9 Underlying technical standards 93 A Further support 95 ...

Страница 6: ...yed in addition to a safety instruction of the type Danger or Warning it means that there is a danger of electric shock and failure to observe the instructions will inevitably result in injury This symbol indicates the danger of hot surfaces on the device In connection with safety instructions non observance of the instructions will inevitably result in injuries DANGER DANGER draws attention to an...

Страница 7: ...onnel to work on the device Qualified personnel have the following characteristics Qualified personnel are properly trained Training as well as practical knowledge and experience make up their qualifications This is the prerequisite for grounding and labeling circuits devices and systems in accordance with current standards in safety technology Qualified personnel are aware of the dangers that exi...

Страница 8: ... are complied with Requirements for connecting the signal contact The following requirements apply without restrictions The electrical wires are voltage free The cables used are permitted for the temperature range of the application case First connect the ground screw on the back of the device with the protective conductor before you set up the other connections When removing the connections you r...

Страница 9: ...protective conductor before connecting the wires for the supply voltages Supply with DC voltage The wire diameter of the power supply cable is at least 1 mm North America AWG16 on the supply voltage input Supply with AC voltage The wire diameter of the power supply cable is at least 0 75 mm North America AWG18 on the supply voltage input The cross section of the ground conductor is the same size a...

Страница 10: ...ential If the neutral conductor is not connected to the ground potential also install an external fuse in the neutral conductor Regarding the properties of this fuse See Technical data on page 74 Power supply module characteristic value P All of the following requirements are complied with The power supply complies with the requirements for a safety extra low voltage SELV as per IEC EN 60950 1 The...

Страница 11: ...ctrical Code NEC NFPA 70 article 501 CEC Appendix J Annex J 18 The earth conductor must be at least the same wire size mm or AWG as the supply con ductors WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR HAZARDOUS LOCATIONS OR EXPLOSIVE ATMOSPHERES WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NO...

Страница 12: ...nce Ccable plus non incendive equipment capacitance Ci must be less than the marked capacitance Ca or Co shown on any associated apparatus used The same applies for inductance Lcable Li and La or Lo respectively Where the cable capacitance and inductance per foot are not known the following values shall be used Ccable 60 pF ft 196 85 pF m Lcable 0 2 μH ft 0 66 μH m Table 1 Non incendive Equipment ...

Страница 13: ...uts Avertissement Risque d explosion Ne pas débrancher tant que le circuit est sous tension à moins que l emplacement soit connu pour ne contenir aucune concentration de gaz inflammable Avertissement Risque d explosion La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I division 2 Shielded ground The shielded ground wire of the twisted pairs cabl...

Страница 14: ...e in the maximum surrounding air temperature and stacking devices When installing the device make sure there is at least one free rack space approx 5 cm above the device because heat is discharged via the housing of the device If you are operating the device in a 19 switch cabinet install sliding mounting rails for supporting the weight of the device Installation site requirements Operate the devi...

Страница 15: ...ired to take appropriate measures Note The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values Device variant Directive All variants 2011 65 EU and 2015 863 EU RoHS Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment All va...

Страница 16: ...e undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and...

Страница 17: ...escription safety instructions a description of the display and the other information that you need to install the device Documentation mentioned in the User Manual Installation that is not supplied with your device as a printout can be found as PDF files for downloading on the Internet at https www doc hirschmann com ...

Страница 18: ...18 Installation GREYHOUND Switch Release 07 10 2020 Legend The symbols used in this manual have the following meanings Listing Work step Subheading ...

Страница 19: ... Ethernet networks according to standard IEEE 802 3 Basic device Figure 1 Basic device Device variants You can choose from between a wide range of variants You have the option to set up your device individually based on different criteria Number of ports Transmission speed Types of connectors Temperature range Supply voltage range Certifications You have numerous options of combining the device ch...

Страница 20: ... supply modules Power supply module variants You have the option to select either 1 or 2 power supply modules with different input voltages Low Voltage Power over Ethernet PoE High Voltage You obtain the power supply modules as accessories See Order number on page 90 GPS3 P GPS1 K GPS1 C ...

Страница 21: ... additional Fast and or Gigabit Ethernet ports You obtain the media modules as accessories See Order number on page 90 Power 2 1 5 3 4 6 8 7 1 5 3 7 Power 2 4 6 8 Power 2 1 5 3 4 6 8 7 b a b a b a b a Power 1 5 3 7 2 6 4 8 P 2 1 5 3 4 6 8 7 Power 2 1 5 3 4 6 8 7 n n Power 2 4 6 8 1 5 3 7 n Power 2 1 5 3 4 6 8 7 b a b a b a b a b a b a b a b a P 2 1 5 3 4 6 8 7 b a b a b a b a P 2 1 5 3 4 6 8 7 b a...

Страница 22: ...10 2 RJ45 socket for 10 100 1000 Mbit s Twisted Pair connections SFP slot for 1 2 5 Gbit s F O connections 6T6Z 6 6 RJ45 socket for 10 100 1000 Mbit s Twisted Pair connections 4 SFP slots for 1 2 5 Gbit s F O connections and 2 SFP slots for 100 1000 Mbit s connections 13 Temperature range S Standard 32 F 140 F 0 C 60 C C Standard with Conformal Coating 32 F 140 F 0 C 60 C T Extended 40 F 158 F 40 ...

Страница 23: ...r device in a separate overview See table 4 on page 26 20 21 Customer specific version HH Hirschmann standard 22 Hardware configuration S Standard 23 Software configuration E Entry Hirschmann Standard 24 25 Software level 2A HiOS Layer 2 Advanced 3A HiOS Layer 3 Advanced 26 27 Software packages 99 Reserved UR Unicast Routing MR Unicast Multicast Routing 28 32 Software version 06 0 Software version...

Страница 24: ... DC K Rated voltage range 60 V DC 250 V DC Rated voltage range 110 V AC 240 V AC 50 Hz 60 Hz P Rated voltage range 48 V DC PoE 54 V DC PoE 7 Temperature range S Standard 32 F 140 F 0 C 60 C C Standard with Conformal Coating 32 F 140 F 0 C 60 C T Extended 40 F 158 F 40 C 70 C E Extended with Conformal Coating 40 F 158 F 40 C 70 C 8 9 Certificatesand declarations You will find detailed information o...

Страница 25: ... socket for 100 Mbit s F O connections 9 10 Configuration Port 5 and port 7 See configuration of port 1 and port 3 11 12 Configuration Port 2 and port 4 See configuration of port 1 and port 3 13 14 Configuration Port 6 and port 8 See configuration of port 1 and port 3 15 Temperature range S Standard 32 F 140 F 0 C 60 C C Standard with Conformal Coating 32 F 140 F 0 C 60 C T Extended 40 F 158 F 40 ...

Страница 26: ... 34 EU X X CE X X X X X X X X X X X X X X EN 60950 1 X X X X X X X X X X X X X X EN 61131 2 X X X X X X X X X X X X X X FCC X X X X X X X X X X X X X X ISA 12 12 01 Class I Div 2 X X cUL 60950 1 X X X X X X X X Substation applications IEC 61850 3 X X IEEE 1613 X X Navy applications DNV GL X X X X Railway applications trackside EN 50121 4 X X X X Table 4 Assignment application cases certificates an...

Страница 27: ...ections 11 V 24 interface 12 USB interface 13 Slot for the SD card 14 Brackets with fastening screws pre mounted Front view characteristic value AT2Z 1 LED display elements for device status 2 Display elements for power supply module status 3 Out of band management port 4 SFP slot for 1 2 5 Gbit s F O connections 5 RJ45 socket for 10 100 1000 Mbit s Twisted Pair connections 6 Cover panel for media...

Страница 28: ... the signal contact 5 3 pin terminal block for the supply voltage characteristic value H 6 Grounding screw Front view characteristic value 6T6F and AT2Z 1 Cover panel for power supply module slot 1 2 Cover panel for power supply module slot 2 3 LED display elements for device status 4 LED display elements for port status 5 Display elements for power supply module status 6 V 24 interface 7 Out of b...

Страница 29: ...n terminal block for the supply voltage characteristic value H 12 Brackets with fastening screws pre mounted Rear view characteristic value AT2Z 1 Grounding screw 2 2 pin terminal block for the supply voltage characteristic value L 3 SFP slot for 1 2 5 Gbit s F O connections 4 RJ45 socket for 10 100 1000 Mbit s Twisted Pair connections 5 Cover panel for media module slot 1 6 Cover panel for media ...

Страница 30: ...30 Installation GREYHOUND Switch Release 07 10 2020 1 3 3 Power supply modules Figure 4 Power supply modules Power supply module variants GPS3 P GPS1 K GPS1 C ...

Страница 31: ...See Media modules on page 25 GMM20 VVUUMMNN Port Port description 1 3 2 DSC singlemode socket 5 7 2 ST singlemode socket 2 4 2 DSC multimode socket 6 8 2 ST multimode socket GMM30 MMNNTTTT GMM32 MMNNTTTT Port Port description 1 3 2 DSC multimode socket 5 7 2 ST multimode socket 2 4 2 RJ45 socket 6 8 2 RJ45 socket 1 2 4 6 8 3 5 7 6 6 4 4 2 2 8 8 1 1 3 3 5 5 7 7 ...

Страница 32: ...TTTTTTT GMM42 TTTTTTTT Port Port description 1 3 2 RJ45 socket 5 7 2 RJ45 socket 2 4 2 RJ45 socket 6 8 2 RJ45 socket GMM40 OOOOOOOO Port Port description 1 3 2 SFP slot 5 7 2 SFP slot 2 4 2 SFP slot 6 8 2 SFP slot 7 5 3 1 6 4 2 8 7 7 5 5 3 3 1 1 6 6 4 4 2 2 8 8 ...

Страница 33: ...Installation GREYHOUND Switch Release 07 10 2020 33 GMM40 OOOOTTTT GMM42 OOOOTTTT Port Port description 1 3 2 SFP slot 5 7 2 SFP slot 2 4 2 RJ45 socket 6 8 2 RJ45 socket 6 4 2 8 7 5 3 1 ...

Страница 34: ...xemplary The sequence of the port numbering is identical for every device variant Media modules Figure 6 Port assignments Media module port assignments Note The port assignment pictured is exemplary The sequence of the port numbering is identical for every device variant MAC ADDRESS V 24 USB z SD 10 11 12 MGMT P ACA RM Status P1 P2 1 2 5 6 7 4 3 8 9 0 5669 pt Power 2 1 5 3 4 6 8 7 ...

Страница 35: ... device with voltage Figure 7 Power supply Supply voltage characteristic value LL via 2 pin terminal blocks Device variants with characteristic value LL Figure 8 Power supply Supply voltage characteristic value HH via 3 pin terminal blocks Device variants with characteristic value HH GRS1042 GRS1142 GRS1042 GRS1142 ...

Страница 36: ... Power supply Supply voltage characteristic value HL via one 2 pin and one 3 pin terminal block Device variants with characteristic value HL You will find information on connecting the supply voltage here Connecting the terminal blocks on page 59 GRS1042 GRS1142 ...

Страница 37: ...nts switch a contact You can also use the management to switch the signal contact manually and thus control external devices 1 6 Ethernet ports You can connect end devices and other segments to the device and media module ports using twisted pair cables or optical fibers F O 1 6 1 1 2 5 Gbit s F O port This port is an SFP slot The port allows you to connect network components according to the IEEE...

Страница 38: ...ll duplex when using a Fast Ethernet SFP transceiver 1000 Mbit s full duplex when using a Gigabit Ethernet SFP transceiver 1 6 3 100 Mbit s F O port This port is an SFP slot or an ST or DSC socket The 100 Mbit s F O port allows you to connect network components according to the IEEE 802 3 100BASE FX standard This port supports 100 Mbit s half duplex mode 100 Mbit s full duplex mode Default setting...

Страница 39: ...information on the pin assignment in a separate overview See Pin assignments on page 40 1 6 5 Support of PoE Prerequisites for the support of PoE PoE Minimum 1 power supply module GPS3 P is installed in the basic device Minimum 1 media module with Poe PoE functionality GMM32 or GMM42 is installed in the basic device Note Poe PoE is exclusively available with PoE capable media modules The GREYHOUND...

Страница 40: ...it s half duplex 10 Mbit s full duplex The port allows you to manage the device and upload configurations via the following protocols SNMP SSH Telnet FTP SCP HTTP HTTPS For more information see the Command Line Interface reference manual You can download the manual on the Internet at the Hirschmann product pages http www hirschmann com 1 7 Pin assignments Basic device RJ45 Pin 10 100 Mbit s 1000 M...

Страница 41: ...nitializes the device Afterwards the device performs a self test During this process various LEDs light up RJ45 Pin 10 100 Mbit s 1000 Mbit s PoEa a Exclusively on PoE capable media modules MDI X mode 1 RX BI_DB Negative VPSE 2 RX BI_DB Negative VPSE 3 TX BI_DA Positive VPSE 4 BI_DD 5 BI_DD 6 TX BI_DA Positive VPSE 7 BI_DC 8 BI_DC 1 2 3 4 5 6 7 8 ...

Страница 42: ...evice is ready for operation Device has detected at least one error in the monitoring results flashes 1 time a period The boot parameters used when the device has been started differ from the boot parameters saved Start the device again flashes4times a period Device has detected a multiple IP address RM Ring Manager none No redundancy configured green lights up Redundancy exists flashes 1 time a p...

Страница 43: ...r supply Supply voltage 1 and 2 is on Device variants with single power supply Supply voltage is on P1 Supply voltage none At least one of the following cases applies Power supply module is not connected to slot P1 There is no external supply voltage or it is too low No internal supply voltage green lights up Power supply module is connected to slot P1 Boot procedure started Valid supply voltage c...

Страница 44: ...is switched to stand by flashes 3 times a period Port is switched off yellow flashing alternately Device is transmitting and or receiving data lights up Device detects a non supported SFP transceiver or a non supported data rate flashes 1 time a period Device detects at least one unauthorized MAC address Port Security Violation and sends a trap flashes 3 times a period The device deactivates the r...

Страница 45: ...ing commands in the CLI To change to the LED display on the service panel execute the following commands in the CLI LED display Position on the device Service panel Only device variants GRS1142 Port panel GRS1042 GRS1142 enable Change to the privileged EXEC mode configure Change to the configuration mode system port led mode portpanel Change LED display from service panel to port panel enable Chan...

Страница 46: ... L D Link state data traffic none Device detects an invalid or missing link green lights up Device detects a valid link flashes 1 time a period Port is switched to stand by flashes 3 times a period Port is switched off yellow lights up Device detects a non supported SFP transceiver or a non supported data rate flashing Device is transmitting and or receiving data flashes 1 time a period Device det...

Страница 47: ...a valid link flashes 1 time a period Port is switched to stand by flashes 3 times a period Port is switched off yellow lights up Device detects a non supported SFP transceiver or a non supported data rate flashing Device is transmitting and or receiving data flashes 1 time a period Device detects at least one unauthorized MAC address Port Security Violation PoE PoE status green lights up Powered d...

Страница 48: ...orresponding terminal emulation This enables you to set up a connection to the Command Line Interface CLI and to the system monitor The socket housing is electrically connected to the front panel of the device The V 24 interface is electrically insulated from the supply voltage VT100 terminal settings Speed 9600 Baud Data 8 bit Stopbit 1 bit Handshake off Parity none Figure Pin assignment Function...

Страница 49: ...nformation and for loading the software See Accessories on page 91 On the front of the device there is an LED display that informs you about the status of the interface The USB interface has the following properties Supplies current of max 500 mA Voltage not potential separated Connectors type A Supports the USB master mode Supports USB 2 0 Figure Pin Function 1 VCC VBus 2 Data 3 Data 4 Ground GND...

Страница 50: ...ard interface Location on the device The SD card interface allows you to connect the AutoConfiguration Adapter ACA31 storage medium This is used for saving loading the configuration data and diagnostic information and for loading the software On the front of the device there is an LED display that informs you about the status of the interface GRS1142 GRS1042 ...

Страница 51: ...ce Connecting the terminal blocks Operating the device Installing an SFP transceiver optional Connecting data cables Filling out the inscription label 2 1 Checking the package contents Check whether the package includes all items named in the section Scope of delivery on page 90 Check the individual parts for transport damage 2 2 Installing the SD card optional Prerequisite Only use the AutoConfig...

Страница 52: ...appable Figure 17 Installing a power supply module Installation sequence Proceed as follows Remove the cover panel if mounted from the power supply module slot on the device 1 Insert the power supply module straight into the slot 2 Fasten the power supply module to the device by tightening the 2 screws 3 You find the prescribed tightening torque in chapter General technical data on page 74 2 1 3 ...

Страница 53: ...d or Gigabit Ethernet ports You have the option of mounting the media modules while the device is operating Figure 18 Installing a media module optional Installation sequence Proceed as follows Remove the cover panel from the media module slot on the basic device Open the locking mechanism of the media module by pressing the locking levers outwards 1 Insert the media module straight into the media...

Страница 54: ...as follows Place the matching cover panel over the power supply module slot or media module slot of the device Fasten the cover panel to the device by tightening the 2 screws You find the prescribed tightening torque in chapter General technical data on page 74 2 6 Installing and grounding the device You have the following options for mounting your device Mounting in a switch cabinet Mounting on a...

Страница 55: ...to vibration For more information on sliding mounting rails and how to install them please contact your switch cabinet manufacturer The devices are designed to be mounted in a 19 switch cabinet In the delivery state there are 2 pre mounted mounting brackets on the sides of the device Ensure adequate ventilation If necessary install an additional fan in the switch cabinet to prevent the device from...

Страница 56: ...ls 1 device 2 sliding mounting rail 3 19 switch cabinet Proceed as follows Assemble the sliding or mounting rails in the 19 switch cabinet as specified by the manufacturer Position the device on the rails in the switch cabinet Fasten the device in the switch cabinet by screwing it in with the mounting brackets 1 3 2 ...

Страница 57: ...dditionally attach 2 brackets to the back of the device You obtain the additional brackets as accessories See Accessories on page 91 Fasten the device by screwing the brackets to the wall WARNING FIRE HAZARD Install the device in a fire enclosure according to EN 60950 1 if you install the device vertically Failure to follow these instructions can result in death serious injury or equipment damage ...

Страница 58: ...echnical data on page 74 Note Applies to device variants featuring supply voltage characteristic value P With redundant power supply with 2 power supply modules GPS3 P supply voltage characteristic value P The use of power sources with a grounded positive power supply conductor is prohibited Note Applies to device variants featuring supply voltage with characteristic value H The device is grounded...

Страница 59: ...ble power supply modules positive grounding is prohibited WARNING ELECTRIC SHOCK Start connecting electrical wires only if all safety requirements listed in chapter General safety instructions are fulfilled Failure to follow these instructions can result in death serious injury or equipment damage WARNING ELECTRIC SHOCK Never insert pointed objects narrow screwdrivers wires etc into the device or ...

Страница 60: ...t terminal blocks P1 and P2 for the corresponding slots P1 and P2 For every supply voltage to be connected perform the following steps Remove the terminal connector from the device Connect the wires according to the pin assignment on the device with the clamps See Supply voltage with characteristic value LL See Supply voltage with characteristic value HH See Supply voltage with characteristic valu...

Страница 61: ...ons Type of the voltages that can be connected Specification of the supply voltage Pin assignment DC voltage P1 P2 Rated voltage range 24 V DC 48 V DC 48 V DC 54 V DC Plus terminal of the supply voltage Minus terminal of the supply voltage Table 7 Supply voltage with characteristic value LL type and specification of the supply voltage connections X z RELAY P2 P1 GRS1142 GRS1042 P1 P2 ...

Страница 62: ... the supply voltage Pin assignment DC voltage P1 P2 Rated voltage range 60 V DC 250 V DC L N Plus terminal of the supply voltage Minus terminal of the supply voltage Protective conductor AC voltage P1 P2 Rated voltage range 110 V AC 240 V AC 50 Hz 60 Hz L N Outer conductor Neutral conductor Protective conductor Table 8 Supply voltage with characteristic value HH type and specification of the suppl...

Страница 63: ... V DC 250 V DC L N Plus terminal of the supply voltage Minus terminal of the supply voltage Protective conductor AC voltage P1 Rated voltage range 110 V AC 240 V AC 50 Hz 60 Hz L N Outer conductor Neutral conductor Protective conductor DC voltage P2 Rated voltage range 24 V DC 48 V DC 48 V DC 54 V DC Plus terminal of the supply voltage Minus terminal of the supply voltage Table 9 Supply voltage ch...

Страница 64: ...2020 2 7 2 Signal contact Figure 24 Signal contact 2 pin terminal block with screw locking Connect the signal contact lines with the terminal block connections Fasten the wires in the terminal block by tightening the terminal screws GRS1042 GRS1142 ...

Страница 65: ...irschmann SFP transceivers See Accessories on page 91 Figure 25 Installing SFP transceivers Installation sequence Proceed as follows Take the SFP transceiver out of the transport packaging 1 Remove the protection cap from the SFP transceiver 2 Push the SFP transceiver with the lock closed into the slot until it latches in 3 3 ...

Страница 66: ... according to your requirements When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify that power supply cables and data cables do not run parallel over longer distances If reducing the inductive coupling is necessary verify that the power supply cables and data cables cross at a 90 a...

Страница 67: ...d further information about the applications HiView or Industrial HiVision on the Internet at the Hirschmann product pages HiView http www hirschmann com en QR INET HiView Industrial HiVision http www hirschmann com en QR INET Industrial HiVision Default settings IP address The device looks for the IP address using DHCPa Password for management Login user password public read only Login admin pass...

Страница 68: ...assword private The device prompts you to type in a new password Type in your new password To help increase security choose a password that contains at least 8 characters which includes upper case characters lower case characters numerical digits and special characters When you log on to the device with the Command Line Interface then the device prompts you to confirm you new password Log on to th...

Страница 69: ...n 5 cm from the device It depends on the installation conditions of the device for example the distance from other devices or other objects and the output of neighboring devices The temperature displayed in the CLI and the GUI is the internal temperature of the device It is higher than the ambient air temperature The maximum internal temperature of the device named in the technical data is a guide...

Страница 70: ...fuses are triggered only in the case of a detected error in the device In case of damage or malfunction of the device turn off the supply voltage and return the device to the plant for inspection Hirschmann is continually working on improving and developing their software Check regularly whether there is an updated version of the software that provides you with additional benefits You find informa...

Страница 71: ...sequence Proceed as follows Remove the screws on the front panel of the power supply module 1 Pull the power supply module out of the slot 2 Seal the power supply module slot on the basic device with a cover panel 3 Fasten the cover panel using the 2 screws on the basic device You find the prescribed tightening torque in chapter General technical data on page 74 1 2 3 ...

Страница 72: ...e front panel of the media module Open the locking mechanism of the media module by pressing the locking levers outwards 1 2 Pull the media module out of the slot 3 Close the media module slot on the basic device using a cover panel Fasten the cover panel using the 2 screws on the basic device You find the prescribed tightening torque in chapter General technical data on page 74 3 2 1 ...

Страница 73: ...ism 2 Close the SFP transceiver with the protection cap 3 6 4 Removing the device Proceed as follows Disconnect the data cables Disable the supply voltage Disconnect the terminal blocks Disconnect the grounding To detach the device from the switch cabinet or the wall remove the screws from the brackets on the device WARNING ELECTRIC SHOCK Disconnect the grounding only after disconnecting all other...

Страница 74: ... H Rated voltage range 110 V AC 240 V AC 50 Hz 60 Hz 60 V DC 250 V DC Back up fuse for each voltage input Nominal rating Characteristic 2 5 A slow blow Connection type 3 pin terminal block Tightening torque 4 4 lb in 0 5 Nm min conductor diameter Supply with DC voltage AWG16 1 mm Supply with AC voltage AWG18 0 75 mm max conductor diameter AWG12 2 5 mm Grounding the device Tightening torque Protect...

Страница 75: ...non condensing Air pressure min 700 hPa 9842 ft 3000 m max 1060 hPa 1312 ft 400 m Pollution degree 2 Protection classes Laser protection Class 1 in compliance with IEC 60825 1 Degree of protection IP30 a Not UL 60950 certified b Not UL 60950 certified c Temperature of the ambient air at a distance of 2 in 5 cm from the device d If you are using SFP modules without the EEC extension an operating te...

Страница 76: ...Power loss buffer 17 ms at 110 V AC 20 ms at 230 V AC Overload current protection on the device Non replaceable fuse Peak inrush current 3 A 1 ms Current integral I t 0 3 A2 s Crest factor 1 8 Power supply module characteristic value P The supply voltage inputs are designed for operation with safety extra low voltage Connect only SELV circuits with voltage restrictions in line with IEC EN 60950 1 ...

Страница 77: ... 185 W Climatic conditions during operation Ambient temperature Devices with operating temperature characteristic value S Standard 32 F 140 F 0 C 60 C a a Hirschmann recommends to use SFP transceivers with EEC extension Devices with operating temperature characteristic value C standard with Conformal Coating 32 F 140 F 0 C 60 C b b Hirschmann recommends to use SFP transceivers with EEC extension D...

Страница 78: ...0 2020 7 2 Dimension drawings Basic device Figure 29 Basic device Dimension drawing device variant characteristic value 6T6Z with 2 power supply module GPS3 P 354 14 94 378 5 17 9 483 19 10 0 39 mm inch 466 18 35 444 17 5 32 1 26 44 1 73 6 9 0 27 ...

Страница 79: ...haracteristic value AT2Z with 2 power supply module GPS1 C Note The dimensions of the basic device is identical for every device variant Differences result exclusively from the different dimensions of the power supply module variants 354 14 94 483 19 10 0 39 mm inch 466 18 35 444 17 5 32 1 26 44 1 73 6 9 0 27 ...

Страница 80: ...gure 31 Power supply modules Dimension drawing power supply module GPS1 C GPS1 K Figure 32 Power supply modules Dimension drawing power supply module GPS3 P 167 6 58 173 6 81 8 0 32 42 1 65 109 4 29 116 5 4 59 mm inch 167 6 58 173 6 81 109 4 29 141 5 55 8 0 32 42 1 65 mm inch ...

Страница 81: ...llation GREYHOUND Switch Release 07 10 2020 81 Media modules Figure 33 Media modules Dimension drawing media modules exemplary 130 5 12 115 4 53 4 0 16 129 5 08 mm inch 135 5 32 41 5 1 63 37 5 1 48 140 5 51 ...

Страница 82: ...L Guidelines EMC 1 FCC 47 CFR Part 15 Class A Class A Class A Class A EN 61000 6 4 Fulfilled Fulfilled Fulfilled Fulfilled Conducted emission EN 55032 DC supply connection Class A Class A Class A Class A DNV GL Guidelines DC supply connection EMC 1 FCC 47 CFR Part 15 DC supply connection Class A Class A Class A Class A EN 61000 6 4 DC supply connection Fulfilled Fulfilled Fulfilled Fulfilled EN 55...

Страница 83: ...V EN 61000 4 4 IEEE C37 90 1 Data line 4 kV 4 kV 2 kV 4 kV Voltage surges DC supply connection EN 61000 4 5 line ground 2 kV 2 kV 2 kV 2 kV IEEE 1613 line ground 5 kV EN 61000 4 5 line line 1 kV 1 kV 1 kV 1 kV Voltage surges data line EN 61000 4 5 line ground 1 kV 1 kV 2 kV 2 kV Conducted disturbances EN 61000 4 6 150 kHz 80 MHz 10 V 10 V 10 V 10 V EMC interference immunity Standard applicationsa ...

Страница 84: ...munity Standard applicationsa a EN 61131 2 CE FCC applies to all devices Merchant Navy b b Merchant Navy applies to devices with the approval codes U9 UT UX UY VU Railway applications trackside c c EN 50121 4 applies to devices with the approval codes VT T9 TY S9 SY Substation applications d d EN 61850 3 IEEE 1613 applies to devices with the certification codes V9 VY VU VT IEC 60068 2 6 test Fc Vi...

Страница 85: ... 0 km 50 km 1 0 dB km 500 MHz km LX LC MM 1310 nmd d With F O adapter compliant with IEEE 802 3 2002 Clause 38 single mode fiber offset launch mode conditioning patch cord 50 125 µm 0 dB 10 5 dB 0 mi 0 34 mi 0 km 0 55 km 1 0 dB km 800 MHz km LX LC MM 1310 nme e With F O adapter compliant with IEEE 802 3 2002 Clause 38 single mode fiber offset launch mode conditioning patch cord 62 5 125 µm 0 dB 10...

Страница 86: ... ps nm km Table 11 F O port bidirectional Gigabit Ethernet SFP transceiver Product code Modea Wave length Fiber System attenuation Example for F O line lengthb Fiber attenuation BLP Dispersion M FAST SFP MM LC MM 1310 nm 50 125 µm 0 dB 8 dB 0 mi 3 11 mi 0 km 5 km 1 0 dB km 800 MHz km M FAST SFP MM LC MM 1310 nm 62 5 125 µm 0 dB 11 dB 0 mi 2 49 mi 0 km 4 km 1 0 dB km 500 MHz km M FAST SFP SM LC SM ...

Страница 87: ...B 4 dB 0 34 mi 0 55 km 3 5 dB km 2000 MHz km OM3 MM LC EEC MM 850 nm 50 125 µm 0 dB 4 dB 0 25 mi 0 4 km 3 5 dB km 500 MHz km OM2 MM LC EEC MM 850 nm 62 5 125 µm 0 dB 4 dB 0 11 mi 0 17 km 3 5 dB km 200 MHz km OM1 SM LC EEC SM 1310 nm 9 125 µm 0 dB 8 5 dB 3 11 mi 5 km 0 4 dB km 3 5 ps nm km SM LC EEC SM 1310 nm 9 125 µm 0 dB 13 dB 12 43 mi 20 km 0 4 dB km 3 5 ps nm km SM LC EEC SM 1310 nm 9 125 µm 1...

Страница 88: ...plexing typically have filters which use up the remaining attenuation budget For point to point connections without filters and with max 1 5 dB of connector losses the max F O connection length is 59 mi 95 km 10 100 1000 Mbit s twisted pair port Length of a twisted pair segment max 328 ft 100 m for Cat5e cable Table 14 Network range 10 100 1000 Mbit s twisted pair port ...

Страница 89: ...T2Z GRS1042 6T6Z GRS1142 6T6Z Power supply modules GPS1 K 2 5 W 9 Btu IT h GPS1 C 3 5 W 12 Btu IT h GPS3 P 5 5 W 19 Btu IT h Media modules GMM20 XXXXXXXX 10 W 34 Btu IT h GMM30 XXXXTTTT 6 5 W 22 Btu IT h GMM32 XXXXTTTT 8 5 W 29 Btu IT h GMM40 OOOOTTTT 5 5 W 19 Btu IT h GMM42 OOOOTTTT 7 5 W 26 Btu IT h GMM40 OOOOOOOO 7 5 W 26 Btu IT h GMM40 TTTTTTTT 3 5 W 12 Btu IT h GMM42 TTTTTTTT 5 5 W 19 Btu IT ...

Страница 90: ...voltage with characteristic value LL 2 3 pin terminal block for the supply voltage only for device variants featuring supply voltage with characteristic value HH 1 2 pin terminal block for the supply voltage 3 pin terminal block for the supply voltage only for device variants featuring supply voltage with characteristic value HL GREYHOUND Switch 942 135 999 GREYHOUND power supply modules 942 136 9...

Страница 91: ...LH LC EEC 943 898 001 M SFP LH LC 943 049 001 SFP GIG LX LCa a You find further information on certifications on the Internet at the Hirschmann product pages www hirschmann com 942 196 001 SFP GIG LX LC EECa 942 196 002 2 5 Gigabit Ethernet SFP transceiver applies exclusively to the basic device Order number M SFP 2 5 MM LC EEC 942 162 001 M SFP 2 5 SM LC EEC 942 163 001 M SFP 2 5 SM LC EEC 942 16...

Страница 92: ... M FAST SFP SM LC EEC 943 946 001 M FAST SFP SM LC 943 867 001 M FAST SFP SM LC EEC 943 947 001 M FAST SFP LH LC 943 868 001 M FAST SFP LH LC EEC 943 948 001 SFP FAST MM LCa a You will find further information on certifications on the Internet on the Hirschmann product pages www hirschmann com 942 194 001 SFP FAST MM LC EECa 942 194 002 SFP FAST SM LCa 942 195 001 SFP FAST SM LC EECa 942 195 002 T...

Страница 93: ... 1613 IEEE Standard Environmental and Testing Requirements for Communication Networking Devices in Electric Power Substations IEEE 802 3 Ethernet EN 50121 4 Railway applications EMC Emission and immunity of the signaling and telecommunications apparatus Rail Trackside EN 55032 Electromagnetic compatibility of multimedia equipment Emission Requirements EN 60950 1 Information technology equipment Sa...

Страница 94: ...ively if the approval indicator appears on the device casing If your device has a shipping approval according to DNV GL you find the approval mark printed on the device label You will find out whether your device has other shipping approvals on the Hirschmann website at www hirschmann com in the product information ...

Страница 95: ...mann Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification You find the training courses on technology and products cu...

Страница 96: ......

Отзывы: