82
Inst
allation
GREYHOUND Switch
Re
lease
07
10/2
020
7.3
EMC and immunity
EMC interference
emission
Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Merchant Navy
b,c
b. Merchant Navy – applies to devices with the approval codes U9, UT, UX, UY, VU
c. Exclusively use shielded twisted pair cables in areas according to DNV GL EMC Class B.
Railway
applications
(trackside)
d
d. EN 50121-4 – applies to devices with the approval codes VT, T9, TY, S9, SY
Substation
applications
e
e. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
Radiated emission
EN 55032
Class A
Class A
Class A
Class A
DNV GL Guidelines
—
EMC 1
—
—
FCC 47 CFR Part 15
Class A
Class A
Class A
Class A
EN 61000-6-4
Fulfilled
Fulfilled
Fulfilled
Fulfilled
Conducted emission
EN 55032
DC supply connection
Class A
Class A
Class A
Class A
DNV GL Guidelines
DC supply connection
—
EMC 1
—
—
FCC 47 CFR Part 15
DC supply connection
Class A
Class A
Class A
Class A
EN 61000-6-4
DC supply connection
Fulfilled
Fulfilled
Fulfilled
Fulfilled
EN 55032
Telecommunication connections
Class A
Class A
Class A
Class A
EN 61000-6-4
Telecommunication connections
Fulfilled
Fulfilled
Fulfilled
Fulfilled
EMC interference
immunity
Standard
applications
a
Merchant Navy
b
Railway
applications
(trackside)
c
Substation
applications
d
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge
±4 kV
±6 kV
±6 kV
±8 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge
±8 kV
±8 kV
±8 kV
±15 kV
Содержание Hirschmann GREYHOUND GMM20