Страница 1: ...16TX Release 02 12 2014 Technical Support https hirschmann support belden eu com User Manual Installation Industrial Ethernet Rail Switch SPIDER II 16TX EEC SPIDER II 16TX 2DS S EEC SPIDER II 16TX EEC SPIDER II 16TX 2DS S EEC ...

Страница 2: ...e performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy...

Страница 3: ...ts 14 2 Installation 15 2 1 Checking the package contents 15 2 2 Installing and grounding the device 15 2 2 1 Installing the device onto the DIN rail 15 2 2 2 Grounding the device 16 2 3 Wiring the terminal block for the supply voltage and the grounding 17 2 4 Operating the device 18 2 5 Connecting data cables 18 2 6 Installing an SFP transceiver optional 19 2 7 Removing the SFP transceivers 19 3 ...

Страница 4: ...4 Installation SPIDER II 16TX Release 02 12 2014 ...

Страница 5: ...onnel have the following characteristics Qualified personnel are properly trained Training as well as practical knowledge and experience make up their qualifications This is the prerequisite for grounding and labeling circuits devices and systems in accordance with current standards in safety technology Qualified personnel are aware of the dangers that exist in their work Qualified personnel are f...

Страница 6: ...tage inputs are designed for operation with safety extra low voltage Connect only SELV circuits with voltage restric tions in line with IEC EN 60950 1 to the supply voltage connec tions A fuse suitable for DC voltage is located in the plus conductor of the power supply Regarding the properties of this fuse See General technical data on page 22 The wire diameter of the power supply cable is at leas...

Страница 7: ... II 16TX 2DS S EEC LED or LASER components according to IEC 60825 1 2007 CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT Only use SFP transceiver which are limited to the laser class 1 CE marking The labeled devices comply with the regulations contained in the following European directive s 2011 65 EU RoHS Directive of the European Parliament and of the Council on the restriction of the use of certain h...

Страница 8: ...r the area is known to be non hazardous WARNING EXPLOSION HAZARD Substitution of any components may impair suitability for Class I Division 2 Relevant for use in Ex Zone 2 according to ATEX 95 European directive 94 9 EC Any unauthorized modifications to or use of this equipment outside its specified mechanical electrical or other operating limits may cause personal injury and or property damage in...

Страница 9: ...evice must accept any interference received including interference that may cause undesired operation Appropriate testing has established that this device fulfills the require ments of a class A digital device in line with part 15 of the FCC regula tions These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The...

Страница 10: ...ual document contains a device description safety instructions a display description and other information that you require to install the device before starting with the configuration of the device Legend The symbols used in this manual have the following meanings Listing Work step Subheading ...

Страница 11: ...ng various media to connect to the terminal devices and other network components twisted pair cable multimode F O singlemode F O The Hirschmann network components help you ensure continuous commu nication across all levels of the company 1 2 Description of the device variants The devices differ with regard to the number of interfaces and the media type for connecting segments The table below shows...

Страница 12: ...ossing 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode The green and yellow LEDs at the individual twisted pair ports provide port related information 1 5 pin pluggable terminal block for redundant power supply 2 LED display elements 3 RJ45 socket for 10 100 Mbit s twisted pair connections 4 SFP slot for 100 1000 Mbit s F O connection T...

Страница 13: ...ull duplex mode Default setting Full duplex When a Gigabit Ethernet transceiver is used this port supports Full duplex mode Autonegotiation Delivery state Autonegotiation active Note Verify that you connect only optical ports with the same optical trans mission properties with each other LED Display Color Activity Meaning 100 Data rate Yellow Lights up 100 Mbit s connection None 10 Mbit s connecti...

Страница 14: ... up Device detects a valid link Flashing Device is transmitting and or receiving data None Device detects an invalid or missing link 18 Lights up Device detects a valid link Flashing Device is transmitting and or receiving data None Device detects an invalid or missing link P1 Lights up Supply voltage 1 is on None Supply voltage 1 is off P2 Lights up Supply voltage 2 is on None Supply voltage 2 is...

Страница 15: ...les Installing an SFP transceiver optional 2 1 Checking the package contents Check whether the package includes all items named in the section Scope of delivery on page 26 Check the individual parts for transport damage 2 2 Installing and grounding the device 2 2 1 Installing the device onto the DIN rail Verify that there is at least 4 in 10 cm of space above and below the device Verify that there...

Страница 16: ...ng the device The device is grounded via a 5 pin terminal block Note Ground the device before connecting any other cables Note The shielding ground of the connectable twisted pair cables is connected to the ground connection as a conductor Beware of possible short circuits when connecting a cable section with conductive shielding braiding WARNING ELECTRIC SHOCK Ground the device before connecting ...

Страница 17: ...TRIC SHOCK Never insert pointed objects narrow screwdrivers wires etc into the device or into the connection terminals for electric conductors Do not touch the connection terminals Start connecting the electrical wires only if all the above safety require ments are fulfilled See Supply voltage on page 6 Failure to follow these instructions can result in death serious injury or equipment damage Fig...

Страница 18: ...r cables verify that there is a sufficient gap between the power supply cables and the data cables when laid over a long distance Ideally install the cables in separate cable channels Use shielded cables Note Verify that you connect only optical ports with the same optical trans mission properties with each other You can connect end devices and other segments to the device ports using twisted pair...

Страница 19: ...r Push the SFP transceiver with the lock closed into the socket until you hear it latch in Note For this device only use suitable SFP modules from Hirschmann See Accessories on page 26 2 7 Removing the SFP transceivers Pull the SFP transceiver out of the socket by means of the opened lock Close the SFP transceiver with the protective cap 1 2 ...

Страница 20: ...an the lifetime of the product when it is operated normally Operate this device according to the specifications Depending on the degree of pollution in the operating environment check at regular intervals that the ventilation slots in the device are not obstructed Note You will find information about the complaints and returns procedures on the Internet under http www beldensolutions com en Servic...

Страница 21: ...ect the data cables Disable the supply voltage Remove the power connector from the device 4 1 Removing the device from the DIN rail To remove the device from the DIN rail press the device downwards and pull it out from under the DIN rail Figure 2 Removal from the DIN rail ...

Страница 22: ...possible Voltage supply according to Class 2 or EN 60950 1 Limited Power Source 4 A slow blow Peak inrush current 1 3 A Potential differ ence between incoming voltage and housing Potential difference from incoming voltage 24 V DC 32 V DC Potential difference from incoming voltage ground 32 V DC Climatic condi tions during opera tion Ambient air temperatureb b Temperature of the ambient air at a di...

Страница 23: ...ty Electrostatic discharge EN 61000 4 2 IEEE C37 90 3 Contact discharge 4 kV EN 61000 4 2 IEEE C37 90 3 Air discharge 8 kV Electromagnetic field EN 61000 4 3 80 MHz 1000 MHz 10 V m EN 61000 4 3 1 4 GHz 2 GHz 3 V m EN 61000 4 3 2 GHz 2 7 GHz 1 V m Fast transients burst EN 61000 4 4 IEEE C37 90 1 DC supply connection 2 kV EN 61000 4 4 IEEE C37 90 1 Data line 4 kV Voltage surges DC supply connection ...

Страница 24: ...3 dB system reserve when compliance with the fiber data is observed Fiber atten uation BLP dispersion MM LC MM 1310 nm 50 125 µm 0 8 dB 0 5 km 1 0 dB km 800 MHz km MM LC MM 1310 nm 62 5 125 µm 0 11 dB 0 4 km 1 0 dB km 500 MHz km SM LC SM 1310 nm 9 125 µm 0 13 dB 0 25 km 0 4 dB km 3 5 ps nm km SM LC SM 1310 nm 9 125 µm 10 29 dB 25 65 km 0 4 dB km 3 5 ps nm km LH LC SM 1550 nm 9 125 µm 10 29 dB 47 1...

Страница 25: ...lculations c With F O adapter compliant with IEEE 802 3 2002 clause 38 single mode fiber offset launch mode conditioning patch cord d including 2 5 dB system reserve when compliance with the fiber data is observed Product code M SFP BIDI Wave length TX Wave length RX Fiber System attenua tion Example for F O line length a a including 3 dB system reserve when compliance with the fiber data is obser...

Страница 26: ...M FAST SFP SM LC EEC 943 945 501 M FAST SFP LH LC 943 865 501 M FAST SFP LH LC EEC 943 945 501 Gigabit Ethernet SFP transceiver Order number M SFP SX LC 943 014 001 M SFP SX LC EEC 943 896 001 M SFP MX LC EEC 942 108 001 M SFP LX LC 943 015 001 M SFP LX LC EEC 943 897 001 M SFP LX LC 942 023 001 M SFP LX LC EEC 942 024 001 M SFP LH LC 943 042 001 M SFP LH LC EEC 943 898 001 M SFP LH LC 943 049 001...

Страница 27: ...rocess Control Equipment Industrial Products EN 55022 Information technology equipment Radio disturbance character istics Limits and methods of measurement EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic stan dards Immunity for industrial environments EN 61131 2 Programmable controllers Part 2 Equipment requirements and tests EN 60950 1 Information technology equipment Safety Part ...

Страница 28: ...28 Installation SPIDER II 16TX Release 02 12 2014 ...

Страница 29: ...860 E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification The current technology and product training courses c...