78
TEMP_1_CELSIUS=
TEMP_2_CELSIUS=
Temperature in °C
Number
Temperature in
Celsius
Temperature will be
blank if the
temperature sensor is
not enabled.
FAN_1_NAME=
FAN_2_NAME=
Name of Fan
Text
This is set by the
product and are not
user settable.
FAN_1_STATE=
FAN_2_STATE=
Fan State
OK:Low
OK:Medium
OK:High
WARN:Max
FAIL:Stopped
FAIL:ShortCircuit
Fan is running OK.
Low speed mode
Fan is running OK.
Medium speed mode
Fan is running OK
High speed mode
Fan is running at
maximum speed
Fan has ceased
running, Critical
Fan has become short
circuit, Critical
ENCLOSURE=
Enclosure Name
IQH1A, IQH3A, IQH3B,
or IQH3BQ
Displays the name of
the IQ Modular
Enclosure.
MODULE_COMMS=
State of module
comms bus
Number of bus errors
per 20 seconds
Running average of
bus errors, 0 would
indicate good comms.
For IQ Modules, this
bus is I2c.
VOLTAGE_1_NAME=
VOLTAGE_2_NAME=
Voltage rail name
Text
For IQ these are +7.5V
& -7.5V rails.
Field Name
Field Name
Description
Valid Field Values
Usage Description