46
This display does not toggle. If any errors occur, these are specific to the outlet sensor only.
Line 3
This line will show the status of the enclosure cooling fan which is located at the rear of the
unit.
It displays the status and the programmed speed (devised according to the current ambient
temperature) and would normally show:
Error conditions would be shown as below:
Message
Description
TEMP: 28C FAILED
Outlet sensor failure.
TEMP: 28C DISABL
Outlet sensor configured as disabled.
Message
Description
FAN: OK(LOW)
Fan is running OK. Low speed mode.
FAN: OK(MEDIUM)
Fan is running OK. Medium speed mode
FAN: OK(HIGH)
Fan is running OK. High speed mode.
FAN:OK (MAX)
Fan is running OK. Max speed mode. IQH3BQ only.
Note:
If the frame is configured as a Quiet Enclosure,, the speed will
always be displayed as FAN:OK (MAX).
Message
Description
FAN: WARN(MAX)
Fan is running at maximum speed.
FAN: FAIL STOP 1
Fan 1 has ceased running.
FAN: FAIL STOP 2
Fan 2 has ceased running.
FAN: FAIL STOP 1 & 2!
Fans 1 and 2 have ceased running.
FAN: FAIL(SHORT)
Fan short circuit detected.
Содержание grass valley IQH3B Series
Страница 1: ...User Manual Issue 3 Revision 1 2019 07 12 IQH3B IQH3BQ IQ 3U MODULAR ENCLOSURE ...
Страница 14: ...xiv Notices ...
Страница 18: ...xviii Table of Contents ...
Страница 22: ...22 ...
Страница 84: ...84 ...
Страница 88: ...88 ...