3.4.14 The Alarm Config panel
This panel allows the alarm reporting of the HCO-
1822 to be configured. The panel opens in a new
window when the button is clicked, and can be
resized if needed.
The panel is organized in columns.
Status/Name
This contains an expandable tree listing all the
alarms reported by this HCO-1822 card.
•
Each alarm name includes an icon that shows
its current status
•
Some alarms may be text-only and the alarm
status is shown in the name and not by a
status icon, e.g.
The
Overall alarm
and
GSM contribution
columns
contain pulldown lists that allow the level of
contribution of each individual alarm to the alarm
named in the column heading to be set.
Click on the alarm icon to
see the available levels;
then click on one to select it
•
Overall Alarm
This column allows configuration of the
contribution of each individual alarm to the Overall
Alarm associated with this card. The Overall Alarm
is shown in the upper left corner of the iControl
panel, and also appears at the bottom of the
Status/Name column.
•
GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated
with this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for this contribution are related to the Overall alarm contribution:
•
If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any available
value
•
If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to
follow the Overall Alarm.
Figure 3.36 Alarm Configuration Panel