background image

GUIDE TO INSTALLATION AND OPERATION 
 

22

  |  ADX-1901 

Dialnorm:  

this pulldown selects the dialog normalization level. Select OFF to prevent the downmix from applying the 

dialnorm. 

[OFF, -12 dBFS, -13 dBFS, -14 dBFS, ………, -31 dBFS] 

Center Mix Level 

– sets the center channel downmix level to the selected value 

[+3 dB, +1.5dB, 0 dB, -1.5 dB, -3 dB, -4.5 dB, -6 dB, Mute] 

Surround Mix Level

 – sets the surround channels (Ls & Rs) downmix level to the selected value 

[+3 dB, +1.5dB, 0 dB, -1.5 dB, -3 dB, -4.5 dB, -6 dB, Mute]  

LFE Mix Level 

– sets the LFE channels downmix level to the selected value.   

[+10 dB, +9 dB, +7.5 dB, +6 dB, +4.5 dB, +3 dB, +1.5dB, 0 dB, -1.5 dB, -3 dB, -4.5 dB, -6 dB, Mute]

 

 
The block diagram below shows the configuration of the LoRo stereo downmixer. 
 

Surround

Level

Center

Level

+

+

+

+

+

+

+

Ls

Rs

Lo

Ro

L

R

C

Surround

Level

+

LFE

Level

+

+

+

+

LFE

 

 

Figure 5-12 Lo/Ro downmixer

 

 

 

5.8  Loudness Panel 

 
The ADX-1901 allows the user to measure the loudness of audio streams passing through it. The measurement 
process is flexible: 

 

All major loudness standards are supported. 

 

The measurement standards can be customized if desired. 

 

Up to eight programs can be measured at once. 

 

Segment markers can be inserted from two triggers. 

 

Log files of the measurements can be stored externally, for 
analysis using Miranda’s Audio Loudness Analyzer. 

 

5.8.1  Loudness | Config panel 

 
Global Config 

 
All loudness measurements performed by this ADX-1901 are 
performed on the programs defined in th

Audio Programs Panel

using the metering defined and described in that panel.  

 

Global Control 

 
The ADX-1901 can monitor loudness on up to eight programs 
specified by the user. 

 

Figure 5-13 Loudness panel – Config tab

 

Содержание GRASS VALLEY ADX-1901

Страница 1: ...ADX 1901 3G HD SD 8 Channel Analog Audio De Embedder Guide to Installation and Operation M3005 9900 101 2015 04 29...

Страница 2: ...nual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct...

Страница 3: ...the Densit frame control panel 9 4 1 Overview 9 4 2 Menu for local control 10 5 Remote control using iControl 11 5 1 The iControl graphic interface window 11 5 2 Video Input Output panel 13 5 2 1 Vide...

Страница 4: ...panel 30 5 12 Factory Presets panel 31 5 13 Alarm Config panel 33 5 14 Info panel 36 6 Specifications 38 7 Grass Valley Technical Support 40 ANNEX 1 ADX 1901 Local User Interface 41 ANNEX 2 Installing...

Страница 5: ...e with the Densit 3 frame with the metal extender Multiple rear connector panels are available according to your application needs and the chassis type used A fiber input output cartridge is offered a...

Страница 6: ...Figure 1 1 ADX 1901 Functional Block Diagram 1 4 Front Card edge Interface The front card edge of the ADX 1901 incorporates two elements Status LED see section 3 2 Select Button see section 4 Figure...

Страница 7: ...e In this case only a single slot width panel is required Two rear panels are available ADX 1901 3SRP Single slot width panel for Densit 3 ADX 1901 3SRP F Single slot width panel for Densit 3 with fib...

Страница 8: ...3 frame ADX 1901 3RU it will be delivered with an installed adapter that allows it to fit into the taller frame The adapter can be ordered separately and user installed if required Once a matching rea...

Страница 9: ...described below 2 4 2 Summary of rear panel connections ADX 1901 3SRP ADX 1901 3SRP F ADX 1901 DRP ADX 1901 DRP F Single slot width panel Double slot width panel CONNECTORS 3G HD SD IN 1 1 1 1 3G HD...

Страница 10: ...g audio outputs 8 The eight analog audio outputs are balanced outputs via a 26 pin D SUB female connector Pinout for the connector is shown in the table Fiber I O Fiber optic inputs and outputs Rear p...

Страница 11: ...fiber Rx input and Tx output module at 1310 nm with LC PC connectors SFP R LC Single fiber Rx input module with LC PC connector SFP RT W13 LC Single fiber Rx Tx module at 1310 nm with WDM LC PC connec...

Страница 12: ...ADX 1901 affect the LED status If a cell is gray the error condition cannot cause the LED to assume that status If more than one LED status is possible for a particular error condition the status is c...

Страница 13: ...ing controls located on the cards themselves The controller supports remote operation via its Ethernet ports and local operation using its integrated control panel The local control panel is fastened...

Страница 14: ...SC does not exit the menu system To exit re push the SELECT button for the card being controlled If no controls are operated for 30 seconds the controller reverts to its normal standby status and the...

Страница 15: ...ow structure for the ADX 1901 is shown in figure 5 1 The window identification line gives the card type ADX 1901 and the slot number where the card is installed in its Densit frame There are four main...

Страница 16: ...Icon interpretation Icon 1 Manual Card Configuration green Remote card control activated The iControl interface can be used to operate the card yellow Local card control active The card is being contr...

Страница 17: ...hen displays the group s set of parameters Each of the groups is described in detail below Section 3 The lower left corner of the window identifies the Preset currently in use or Custom if none is app...

Страница 18: ...n a receiver SFP module is installed Fiber Output Config This control is only available when a transmitter SFP module is installed The fiber Out 2 selector is only available when a dual transmitter SF...

Страница 19: ...TC 3G HD embedded in the SDI input The Timecode De embedding section provides resources to configure the de embedding process Delay Adjust the timecode delay value to compensate for a 1 to 50 frame of...

Страница 20: ...output state is inactive o De embed the GPI data located on a pre defined user bit within timecode in the incoming SDI signal is de embedded When De embed is selected use the Bit pulldown list to set...

Страница 21: ...Signal Presence indicates the presence of audio in the 16 channels that may be carried in the embedded audio groups Green audio present Gray audio not present for 2 seconds minimum 5 4 1 CH 1 4 5 8 9...

Страница 22: ...el adjustment mixing 5 5 1 1 2 3 4 5 6 7 8 tabs Each of these tabs provides all necessary controls for the output mixers The example shown is for 1 2 output but all panels have the same controls Opera...

Страница 23: ...high level at the output resulting in signal clipping Source A Source B These sub sections allow the source channels A and B to be selected for each output channel Channel CH 1 CH 16 selects the demu...

Страница 24: ...X X OFF This program is not used The graphic at the bottom of the panel illustrates the selected programs and provides pull downs to choose the audio input that feeds each program input Note 1 An inpu...

Страница 25: ...nual Downmix follows the downmix parameters manually configured by the user Level Normalization use the pulldown to select the type of normalization to be applied on the downmix output level OFF Downm...

Страница 26: ...und Level Center Level Ls Rs Lo Ro L R C Surround Level LFE Level LFE Figure 5 12 Lo Ro downmixer 5 8 Loudness Panel The ADX 1901 allows the user to measure the loudness of audio streams passing throu...

Страница 27: ...the Audio Programs tab Note that segment marker triggers in one PGM will generate segment markers in the logs for all PGMs Logging Status Control This panel monitors logging activity for all loggers...

Страница 28: ...of the last 15 seconds of the value of the Short Term yellow trace and Momentary green trace loudness values The bar graph at the right indicates the current Momentary value A reset initiated by a us...

Страница 29: ...d by the status LED on the card edge when a Black Detect alarm is set Choices are Green Yellow Red Flashing Red Zone settings define a zone within which the alarm detection will be applied Line Start...

Страница 30: ...tus LED on the card edge when a DVITC ATC alarm is set Choices are Green Yellow Red Flashing Red 5 9 3 Alarms Audio panel The Audio alarms are detected after the Audio Output stage just before the Dig...

Страница 31: ...continuously present to clear the alarm if it has been set Use the LED Color pulldown to choose the color that will be displayed by the status LED on the card edge when a Max Level alarm is set Choice...

Страница 32: ...o choose the color that will be displayed by the status LED on the card edge when a Silence alarm is set Choices are Green Yellow Red Flashing Red Phase The Phase measurements are limited to adjacent...

Страница 33: ...ons on setting up the overload counter 5 10 2 Meter Ballistics Config tab Type select a type of meter from the pull down list Upper Zone Limits select the crossover level between the upper and middle...

Страница 34: ...e RALM meter display is a small meter that represents the phase correlation factor between the two channels of a pair 180 90 0 5 11 Test panel Use the checkboxes to select whether each output pair has...

Страница 35: ...eset is loaded will change the display to Custom instead of the preset value Select any one of the five presets using the pull down list Click Load to load the contents of the selected User Preset int...

Страница 36: ...file is saved correctly the Transfer Status box on the right of the Copy profile from line will indicate Succeeded against a green background If the file was not saved for some reason the Transfer St...

Страница 37: ...file to line will indicate Succeeded against a green background 5 13 Alarm Config panel This panel allows the alarm reporting of the ADX 1901 to be configured The panel opens in a new window when the...

Страница 38: ...Click in the checkbox to enable logging of alarm events for each individual alarm Levels associated with these alarms The pulldown lists may contain some or all of the following options The alarm mak...

Страница 39: ...with all the other settings Get alarm keys Click this button to open a save dialog where you can save a file containing a list of all alarms on this card and their current values along with an Alarm...

Страница 40: ...that is shown for this ADX 1901 when it appears in iControl applications Short Label type the short form label that iControl uses in some cases 8 characters Source ID type a descriptive name for this...

Страница 41: ...vice for this ADX 1901 to register itself on a user specified Jini lookup service using the following syntax in the data box jini ip_address where ip_address is the ip address of the server running th...

Страница 42: ...nput Output Signal SMPTE 259M C 270 Mb s SMPTE 292M 1 485 1 485 1 001 Gb s SMPTE 424M 2 970 2 970 1 001 Gb s Supported formats SD SMPTE 259M 480i59 94 576i50 HD SMPTE 274M 1080i59 94 1080i50 1080p23 9...

Страница 43: ...2 Refer to SFP module specifications SFP T S13 LC SFP TT S13 LC SFP RT W13 LC SFP RT W15 LC LTC Output 1 Signal SMPTE12M Connector RJ45 Impedance 50 Level 1 Vp p GPI Signal Output 2 Signal Contact clo...

Страница 44: ...1 eurotech grassvalley com China Office hours 9 30 a m 6 00 p m GMT 8 Telephone 86 10 5873 1814 asiatech grassvalley com Playout Automation Europe Middle East Africa UK Office hours 9 00 a m 5 30 p m...

Страница 45: ...OFF DVITC ATC LTC ATC VITC AUTO SD LINE NUMBER 10 20 en 525 7 22 en 625 SD Only TIME CODE DELAY 0 50 unit frame AUDIO METADATA AUDIO META SDID 1 9 AUDIO META DELAY 0 2700 0 47 unit ms sample AUDIO INP...

Страница 46: ...s installed DO NOT LOOK INTO AN OPERATING SFP MODULE S CONNECTORS AS EYE DAMAGE MAY RESULT The SFP module is sensitive to electrostatic discharge ESD It is recommended that you use an ESD preventive w...

Страница 47: ...C fiber optic connector that is plugged into the SFP module and pull it straight out to disengage the optical fiber from the SFP Never pull the fiber optic cable itself as catastrophic damage may occu...

Страница 48: ...er was used to install the ADX 1901 2 A list of loudness monitoring resources will appear including your ADX 1901 3 Click Settings to specify the path to the location where loudness data files will be...

Страница 49: ...ved from the ADX 1901 as described above 1 From your iControl Application iControl Solo or iControl Navigator double click Loudness Analyzer The complete user manual for the Audio Loudness Analyser is...

Отзывы: