GUIDE TO INSTALLATION AND OPERATION
ADX-1901 |
23
Enable Loudness Monitoring
turns all loudness monitoring functions ON or OFF
RESET
resets the measurements, and places a segment marker in the log file (but only if
User Event
is selected in
the Segment Marker area).
RUNNING / PAUSE
shows the current status of the loudness monitoring.
•
Click the button to change the status.
•
PAUSE stops the measurement until the button is clicked again, but keeps the last value for logging and
measurement.
Segment Marker
Select the checkboxes corresponding to the events for which you want a segment marker inserted in the loudness log
file:
•
User Event – a manually-triggered RESET (but not a PAUSE).
•
Target change – a manually-triggered Meter Mode or Target change in the Audio Programs tab.
Note that segment marker triggers in one PGM will generate segment markers in the logs for all PGMs.
Logging Status/Control
This panel monitors logging activity for all loggers connected to the application server associated with this ADX-1901
and its associated Densité frame.
•
The Logging Activity icon will be GREEN when logging activity is detected.
•
The number of loggers connected to the appserver is shown in the data box.
About Log Files
Loudness logs contain data for a period of up to 24 hours. New log files are started when the logging function is
enabled.
5.8.2 Loudness | PGM panel
Eight PGM panels – PGM 1 to PGM 8 – are available. These
panels show the results of loudness measurements made on
this program.
Program Settings & Input Channel Settings
These data boxes show the program definition – the coding
mode and channel selections are those made in the
Figure 5-14 Loudness panel – PGM 1 tab