FMHD-1 Operator’s Manual
BELAR ELECTRONICS LABORATORY, INC.
Page 39
9.3
Updating the FMHD-1 Firmware
Establish a computer connection to the unit using either the RS-232 Port or the RJ-45 Ethernet Jack. See the
previous instructions for connecting to the
FMHD-1
.
With the
Belar
WizWin©
Software
running and connected to the
FMHD-1
the virtual front panel of the unit
should be visible. In the “Connections” Dialog Box click the “Update” Button, a “Update” Dialog Box will appear
showing the
FMHD-1
units current software version and the Files software version. A warning message will
appear if the File software version is the same or older than what is currently in
FMHD-1
unit. To start the update
click the
“Update EPROM”
Button, the front panel of the
FMHD-1
will show the update status.
9.4
Updating the FMHD-1 Lantronix® Ethernet Controller
The Lantronix Ethernet Controller should be updated to version
4.0.0.0
for proper operation of the unit. Establish a
computer connection to the unit using either the RS-232 Port or the RJ-45 Ethernet Jack. See the previous
instructions for connecting to the
FMHD-1
.
With the
WizWin Software
running and connected to the
FMHD-1
the virtual front panel of the unit should be
visible. In the “Connections” Dialog Box click the “Update” Button, a “Update” Dialog Box will appear showing
the
FMHD-1 Lantronix
current software version and the Files software version. To start the update click the
“Update Lantronix”
Button, the front panel of the
FMHD-1
will show the update status.
Содержание FMHD-1
Страница 1: ...BELAR Broadcast Equipment FMHD 1 FM HD RADIO MONITOR ...
Страница 4: ......
Страница 8: ...FMHD 1 Operator s Manual ...
Страница 55: ...FMHD 1 Operator s Manual BELAR ELECTRONICS LABORATORY INC Page 47 ...
Страница 56: ......
Страница 57: ......
Страница 58: ...BELAR ELECTRONICS LABORATORY INC ...