14.2.7 Virtual channels (optional)
The "virtual channels" option offers four additional channels (no HW channels) for the description of calcula-
tions regarding HW channels, virtual channels, and freely definable constants with each other.
Per each virtual channel, up to eight value calculations with three operands each and 2 operations can be
realised.
Possible applications are the calculations of:
•
The specific performance of a system
•
Total consumption of the system (several compressors)
•
Energy costs etc.
For a calculation example and description of the "specific performance", please refer to Section
14.2.7.1 Activate the option "virtual channels"
After having acquired the "virtual channels" option, the latter needs to be activated first.
Main menu
Settings
via BDL
By pressing the
buy
button for "virtual chan-
nels", you will be requested to enter the activa-
tion code.
Please enter your activation code into the text
field and activate it by pressing the
OK
button.