35 / 124 EN
Multi Split Type Air Conditioner / User Manual
5 Installation
Indoor unit
Outdoor unit
Air switch
(purchased seperately)
(purchased seperately)
Outdoor unit power wires
Indoor & Outdoor
connective wires
(A)
Air Switch
(purchased seperately)
(purchased seperately)
Outdoor unit power wires
Outdoor unit
Indoor unit
Indoor & Outdoor
connective wires
Indoor unit
Outdoor unit
Air switch
(purchased seperately)
Air switch
(purchased seperately)
(purchased seperately)
Indoor unit power wires
Indoor & Outdoor
connective wires
Outdoor unit power wires
Indoor unit
Outdoor unit
Air switch
(purchased seperately)
(purchased seperately)
Indoor unit power wires
Indoor & Outdoor
connective wires
(B)
(C)
Indoor unit
Outdoor unit
Air switch
Air switch
(purchased seperately)
(Only for the North American)
(purchased seperately)
(purchased seperately)
Outdoor unit power wires
Indoor & Outdoor
connective wires
(D)
Indoor unit power wires
Air switch
Air switch
Air switch
Air switch
Air switch
Outdoor unit
Outdoor unit
Outdoor unit
Indoor & Outdoor connective
wires (purchased seperately)
Indoor & Outdoor connective
wires (purchased seperately)
Indoor & Outdoor connective
wires (purchased seperately)
Indoor unit
Indoor unit
Indoor unit
(purchased seperately)
(purchased seperately)
(purchased seperately)
(purchased seperately)
(purchased seperately)
Indoor unit power wires
Outdoor unit power wires
Outdoor unit power wires
(Only for the North American)
C
The cographs are for explanation
purpose only. Your machine may
be slightly different. The actual
shape shall prevail.
5�7�2 Outdoor unit wiring
A
WARNING!
Before performing
any electrical or wiring work, turn
off the main power to the system.
1. Prepare the cable for connection
– You must first choose the right cable size. Be
sure to use H07RN-F cables.
C
In North America, choose the
cable type according to the local
electrical codes and regulations.
Minimum Cross-Sectional Area of Power and
Signal Cables (For reference)
Rated Current of
Appliance (A)
Nominal Cross-
Sectional Area
(mm²)
> 3 and ≤ 6
0.75
> 6 and ≤ 10
1
> 10 and ≤ 16
1.5
> 16 and ≤ 25
2.5
> 25 and ≤ 32
4
> 32 and ≤ 40
6
The size of the power supply cable, signal cable,
fuse, and switch needed is determined by the
maximum current of the unit. The maximum
current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate
to choose the right cable, fuse, or switch.