Split-type room air conditioner / Installation Manual
25 / 120 EN
A
Warning
Do not mix up live and null wires
This is dangerous, and can cause the air conditioning unit
to malfunction.
8. After checking to make sure every connection is secure, use the cable clamp to fasten the signal
cable to the unit. Screw the cable clamp down tightly.
9. Replace the wire cover on the front of the unit, and the plastic panel on the back.
C
Note about wiring
The wiring connection process may differ slightly between units.
Step 7: Wrap piping and cables
Before passing the piping, drain hose, and the signal cable through the wall hole, you must bundle
them together to save space, protect them, and insulate them.
1. Bundle the drain hose, refrigerant pipes, and signal cable according to Fig. 5.10.
Indoor Unit
Space behind unit
Refrigerant piping
Insulation tape
Signal wire
Drain hose
Fig. 5.10
Drain hose must be on bottom
Make sure that the drain hose is at the bottom of the bundle. Putting the drain hose at the top of the
bundle can cause the drain pan to overflow, which can lead to fire or water damage.
Do not intertwine signal cable with other wires
While bundling these items together, do not intertwine or cross the signal cable with any other wiring.
5
Indoor unit installation
Содержание BEHPI 090
Страница 2: ......
Страница 52: ...52 120 EN Do not C 11 ...
Страница 60: ......
Страница 110: ...110 120 SI ne Ob nakupu nove naprave bo prodajalec brezplačno prevzel staro napravo C 11 ...
Страница 118: ......
Страница 119: ......
Страница 120: ...www beko com ...